A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy and Reproducibility of Radiographic Images for Assessing Crestal Bone Height of Implants Using the Precision Implant X-ray Locator (PIXRL) Device. | LitMetric

Purpose: Assessment of crestal bone levels around implants is essential to monitor success and health. This is best accomplished with intraoral radiographs exposed at 90 degrees to the long axis of the implant, but this can be challenging to achieve clinically. Radiographic paralleling devices produce orthogonal radiographs but traditionally have required access to the implant body for each exposure. This study was conducted to determine if use of the Precision Implant X-ray Locator (PIXRL), a radiographic paralleling device that indexes the implant at the time of surgical placement, can produce orthogonal radiographs of dental implants more accurately than traditional radiologic techniques for assessing crestal bone levels.

Materials And Methods: Three dental implants were inserted in dry human skulls in supracrestal positions to simulate crestal bone loss (maxillary right first premolar [site 14], maxillary right central incisor [site 11], and mandibular left second premolar [site 35]). The implants were masked with a soft tissue moulage and restored with provisional restorations. Four dental assistants exposed six radiographs using their usual and customary technique and six using the PIXRL device for each implant. A single examiner measured crestal bone levels on the radiographs relative to the implant platform shoulder on the mesial and distal of each implant. Recorded measurements were compared to the known values. Statistical analysis was completed using a generalized linear regression model to analyze the differences, and post-hoc comparisons with pairwise adjustment were applied.

Results: The images produced using the PIXRL device were more accurate overall compared to traditional techniques and were also more consistent. The greater degree of accuracy was statistically significant for all sites with the exception of the mesial measurements of the implant at site 11.

Conclusion: This study demonstrates that the use of the PIXRL device can assist clinicians in obtaining more accurate orthogonal radiographs for assessing crestal bone height and would be a useful tool for researchers utilizing radiographic imaging of implants as a longitudinal measure of implant success and stability.

Download full-text PDF

Source
http://dx.doi.org/10.11607/jomi.5683DOI Listing

Publication Analysis

Top Keywords

crestal bone
24
pixrl device
16
assessing crestal
12
orthogonal radiographs
12
implant
10
bone height
8
precision implant
8
implant x-ray
8
x-ray locator
8
locator pixrl
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!