Background: Frequent premature ventricular complexes (PVC) are related to reversible tachycardia-induced cardiomyopathy. However, the role of arrhythmia burden on the outcome of the catheter ablation has not been fully recognised.
Aim: The aim of this study was to assess the effect of catheter ablation and PVC burden in patients with and without structural heart disease (SHD) on left ventricular ejection fraction (LVEF).
Methods: Transthoracic echocardiography was done before and six months after radiofrequency catheter ablation in 109 consecutive patients (61 men, age 55 ± 17 years) with frequent PVCs. Sixty-five (59.6%) patients had underlying SHD.
Results: The catheter ablation procedure was successful in 93 (85.3%) patients. Baseline PVC burden was higher in patients with SHD (22,267 ± 12,934) compared to those without concomitant SHD (15,546 ± 7888), p = 0.005. Nevertheless, patients with LVEF ≤ 50% at baseline presented greater LVEF recovery (from 44% to 56%) than those with LVEF > 50% at baseline after catheter ablation. In both groups, the LVEF improved (p < 0.001); however, no difference was observed be-tween patients with SHD (5.7% ± 1.37%) and without (4.6% ± 0.96%) SHD; p = 0.89. PVC burden was higher in patients with (24,350 ± 2776 PVC/day) compared to those without (17,588 ± 1970 PVC/day) improvement of LVEF. In multivariate regression analysis PVC burden > 20,000/day (but not age, p = 0.95; gender, p = 0.89; presence of SHD, p = 0.53; QRS complex width of the treated PVC, p = 0.21, LVEF before ablation, p = 0.19; and site of origin, p = 47) predicted improvement in LVEF after successful catheter ablation (odds ratio: 3.53; 95% confidence interval: 1.15-10.75; p = 0.023).
Conclusions: Catheter ablation of frequent PVCs improves left ventricular function in multivariate analysis predicted improvement of LVEF within six months after the successful catheter ablation procedure in patients with PVC burden exceeding 20,000/24 h.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5603/KP.a2017.0058 | DOI Listing |
Rev Port Cardiol
January 2025
Cardiology Department, Hospital Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal.
Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pacing Clin Electrophysiol
January 2025
Aurora Cardiovascular and Thoracic Services, Aurora Sinai/Aurora St. Luke's Medical Centers, Milwaukee, Wisconsin, USA.
Background: Concurrent Micra leadless pacemaker (Medtronic, Minneapolis, Minnesota) implantation and atrioventricular node (AVN) ablation has been shown to be feasible and safe in patients with symptomatic, drug-refractory atrial fibrillation (AF). However, major complications within the 30 days after concurrent Micra implantation and AVN ablation have been reported. We evaluated the efficacy and safety of the concurrent procedure at our institution.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Department of Cardiology, Yan'an Hospital Affiliated to Kunming Medical University, Kunming, Yunnan, P.R. China.
Objective: The Vizigo sheath, a novel visualizable steerable sheath, has been utilized effectively in the clinical management of atrial fibrillation. However, its application in the ablation of typical atrial flutter (AFL) remains unexplored. This study aims to evaluate and compare the efficacy and safety of the Vizigo sheath against a conventional fixed sheath during catheter ablation for typical AFL.
View Article and Find Full Text PDFPacing Clin Electrophysiol
January 2025
Section of Laboratory for Animal Experiments, Institute of Medical Science, Medical Research Support Center, Nihon University, School of Medicine, Tokyo, Japan.
Background: Neither the actual in vivo tissue temperatures reached with a novel contact force sensing catheter with a mesh-shaped irrigation tip (TactiFlex SE, Abbott) nor the safety profile has been elucidated.
Methods: In a porcine model (n = 8), thermocouples were implanted epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava following a right thoracotomy. After chest closure, endocardial ablation was conducted near the thermocouples under fluoroscopic guidance.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!