Purpose: The aim of this study was to determine the diagnostic accuracy, sensitivity and specificity of isolated-check visual evoked potentials (icVEP) in primary open-angle glaucoma (POAG).
Methods: Ninety POAG patients and sixty-six healthy controls were recruited consecutively. All subjects underwent icVEP and visual field testing. Swept icVEP response functions were obtained by increasing contrast in six stimulus steps, recording the electroencephalogram synchronized to the stimulus display's frame rate and calculating the corresponding signal-to-noise ratio (SNR) of the response at the fundamental frequency to evaluate visual function. Depth of modulation of the check luminance was increased as follows: 2, 4, 8, 14, 22 and 32%, about an equal level of standing contrast, so that the pattern appeared and disappeared at a frequency of 10.0 Hz. SNR above 0.85 was deemed to be significant at the 0.1 level and SNR above 1 significant at the 0.05 level.
Results: The results show that SNR is contrast dependent. It significantly rose as contrast increased. The areas under receiver-operating-characteristic curves (AUCs) indicating classification accuracy for all POAG cases in comparison with normal subjects were 0.790 (sensitivity 91.1%, specificity 69.7%) with the cutoff SNR of 0.85, and 0.706 (sensitivity 95.6%, specificity 51.5%) with the cutoff SNR of 1. The AUC of early glaucoma cases (EG) in comparison with normal subjects was 0.801 (sensitivity 93.3%, specificity 69.7%) with the cutoff SNR of 0.85, and 0.717 (sensitivity 97.8%, specificity 51.5%) with the cutoff SNR of 1.
Conclusion: icVEP has good diagnostic accuracy (high sensitivity and moderate specificity) in distinguishing early POAG patients from healthy subjects. It might be a promising device to use in conjunction with complementary functional and structural measures for early POAG detection.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10633-017-9598-6 | DOI Listing |
Sci Bull (Beijing)
September 2024
The γ-ray emission from the W51 complex is widely acknowledged to be attributed to the interaction between the cosmic rays (CRs) accelerated by the shock of supernova remnant (SNR) W51C and the dense molecular clouds in the adjacent star-forming region, W51B. However, the maximum acceleration capability of W51C for CRs remains elusive. Based on observations conducted with the Large High Altitude Air Shower Observatory (LHAASO), we report a significant detection of γ rays emanating from the W51 complex, with energies from 2 to 200 TeV.
View Article and Find Full Text PDFJ Geriatr Cardiol
May 2024
Department of Cardiology, Nanjing First Hospital, Nanjing Hospital Affiliated to Nanjing Medical University, Nanjing Medical University, Nanjing, China.
Objectives: To investigate whether negative remodeling (NR) detected by intravascular ultrasound (IVUS) of the side branch ostium (SBO) would affect in-stent neointimal hyperplasia (NIH) at the one-year follow-up and the clinical outcome of target lesion failure (TLF) at the long-term follow-up for patients with left main bifurcation (LMb) lesions treated with a two-stent strategy.
Methods: A total of 328 patients with de novo true complex LMb lesions who underwent a 2-stent strategy of percutaneous coronary intervention (PCI) treatment guided by IVUS were enrolled in this study. We divided the study into two phases.
Magn Reson Med
November 2024
The Azrieli National Institute for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot, Israel.
Purpose: Non-contrast-enhanced time of flight (TOF) is a standard method for magnetic resonance angiography used to depict vessel morphology. TOF is commonly performed with a 3D steady-state acquisition, employing a short repetition time to support high resolution imaging. At 7 T, TOF exhibits substantial increase in SNR and contrast, improving its clinical value.
View Article and Find Full Text PDFAudiol Neurootol
October 2024
Unité Fonctionnelle Implants Auditifs, Service Oto-Rhino-Laryngologie, GHU Pitié-Salpêtrière, AP-HP/ Sorbonne Université, Paris, France.
Introduction: Auditory performance in noise of cochlear implant recipients can be assessed with the adaptive Matrix test (MT); however, when the speech-to-noise ratio (SNR) exceeds 15 dB, the background noise has any negative impact on the speech recognition. Here, we aim to evaluate the predictive power of aided pure-tone audiometry and speech recognition in quiet and establish cut-off values for both tests that indicate whether auditory performance in noise can be assessed using the Matrix sentence test in a diffuse noise environment.
Methods: Here, we assessed the power of pure-tone audiometry and speech recognition in quiet to predict the response to the MT.
IEEE Trans Biomed Circuits Syst
October 2024
Utilizing injectable devices for monitoring animal health offers several advantages over traditional wearable devices, including improved signal-to-noise ratio (SNR) and enhanced immunity to motion artifacts. We present a wireless application-specific integrated circuit (ASIC) for injectable devices. The ASIC has multiple physiological sensing modalities including body temperature monitoring, electrocardiography (ECG), and photoplethysmography (PPG).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!