Theoretical predictions and computer simulations indicate that it may be impossible to achieve values of the coefficient of variation usually found in large volume parenterals (LVP) when the intrinsic particulate contamination in small volume parenterals (SVP) is investigated. Snap-opened ampoules from Australian manufacturers containing 5, 10 or 20 ml Water for Injections or Sodium Chloride Injection had a high level of particulate contamination, although within the USP XXI SVP limits. Heat-opened ampoules had much lower levels of contamination which were generally below the official LVP limits. Counts ml-1 were typically less than 10 and less than 1 for 5 and 20 micron particles, respectively. Coefficients of variation of the 5 micron data from an ampoule in any batch examined, typically ranged over 30-70%. Statistical analysis of the 5 micron data indicates significant differences between batches. Occasional ampoules had higher 5 micron counts than others in the same batch. At no time were the particulate contamination levels considered to be clinically important.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.2042-7158.1986.tb04517.xDOI Listing

Publication Analysis

Top Keywords

particulate contamination
16
volume parenterals
8
micron data
8
particulate
4
contamination australian
4
ampoules
4
australian ampoules
4
ampoules theoretical
4
theoretical predictions
4
predictions computer
4

Similar Publications

The antiscale magnetic treatment (ASMT) claims to utilize magnetic field to combat scaling. However, its underlying mechanism, effectiveness, and reliability remain controversial. To address these contentious aspects, we analyze the influence of a magnetic field on the different stages of typical scale formation, using [Formula: see text] as a model scale.

View Article and Find Full Text PDF

Hidden Threat in Turbid Waters: Quantifying and Modeling the Bioaccumulation and Risks of Particulate Metals to Clams.

Environ Pollut

January 2025

Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies, State Key Lab of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen, Fujian 361102, China. Electronic address:

A major proportion of metal contaminants in aquatic environments is bound to suspended particulate matter (SPM), yet environmental monitoring typically focuses on dissolved metals, with the filtration step removing SPM. This step may inadvertently hide the potential risks posed by particulate metals. In this study, we used stable isotope tracers to quantify the contributions of SPM-bound metals to the bioaccumulation of nickel (Ni), copper (Cu), zinc (Zn), cadmium (Cd), and lead (Pb) in Ruditapes philippinarum, a widely distributed clam crucial to global aquaculture.

View Article and Find Full Text PDF

Airborne particulate matter inhalation bioaccessibility: A review of methodological aspects.

Chem Biol Interact

January 2025

Department of Environment and Planning, Centre for Environmental and Marine Studies, University of Aveiro, 3810-193 Aveiro, Portugal. Electronic address:

Research has consistently linked exposure to particulate matter (PM) with adverse health outcomes, including cardiovascular and pulmonary morbidity and mortality. Understanding the mechanisms by which PM leads to these effects on human health is crucial for developing effective mitigation strategies. One aspect of PM research that has gained increased attention in the past few years is the bioaccessibility of inhaled PM-bound pollutants that have potential to cause adverse health effects.

View Article and Find Full Text PDF

Microplastics (MP) are known to be ubiquitous. The pathways and fate of these contaminants in the marine environment are receiving increasing attention, but still knowledge gaps exist. In particular, the link between mass-based MP quantification and oceanographic parameters is often lacking.

View Article and Find Full Text PDF

Parenteral drug products manufactured under GMP conditions should be visually inspected for defects and particulate contamination by trained and qualified personnel. Although personnel qualification is required, no practical protocols or formal guidelines are available for the development of qualification test sets (QTSs) used for qualification procedures. The current practice is to either procure a standardized QTS from a commercial supplier or amass sufficient manufacturing rejects during visual inspection procedures to compile in-house QTSs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!