Direct observation of temperature-driven magnetic symmetry transitions by vectorial resolved MOKE magnetometry.

J Phys Condens Matter

IMDEA-Nanociencia, Campus Universidad Autónoma de Madrid, 28049 Madrid, Spain. Departamento de Física de la Materia Condensada and Instituto 'Nicolás Cabrera', Universidad Autónoma de Madrid, 28049 Madrid, Spain.

Published: October 2017

Angle- and temperature-dependent vectorial magnetometry measurements are necessary to disentangle the effective magnetic symmetry in magnetic nanostructures. Here we present a detailed study on an Fe(1 0 0) thin film system with competing collinear biaxial (four-fold symmetry) and uniaxial (two-fold) magnetic anisotropies, carried out with our recently developed full angular/broad temperature range/vectorial-resolved magneto-optical Kerr effect magnetometer, named TRISTAN. The data give direct views on the angular and temperature dependence of the magnetization reversal pathways, from which characteristic axes, remanences, critical fields, domain wall types, and effective magnetic symmetry are obtained. In particular, although the remanence shows four-fold angular symmetry for all investigated temperatures (15 K-400 K), the critical fields show strong temperature and angular dependencies and the reversal mechanism changes for specific angles at a given (angle-dependent) critical temperature, showing signatures of an additional collinear two-fold symmetry. This symmetry-breaking is more relevant as temperature increases to room temperature. It originates from the competition between two anisotropy contributions with different symmetry and temperature evolution. The results highlight the importance of combining temperature and angular studies, and the need to look at different magnetic parameters to unravel the underlying magnetic symmetries and temperature evolutions of the symmetry-breaking effects in magnetic nanostructures.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-648X/aa7f45DOI Listing

Publication Analysis

Top Keywords

magnetic symmetry
12
temperature
9
magnetic
8
effective magnetic
8
magnetic nanostructures
8
critical fields
8
temperature angular
8
symmetry
7
direct observation
4
observation temperature-driven
4

Similar Publications

Nanoscale polarization transient gratings.

Nat Commun

December 2024

Elettra - Sincrotrone Trieste S.C.p.A., S.S. 14 km 163.5 in Area Science Park, 34149, Trieste, Italy.

Light manipulation at the nanoscale is essential both for fundamental science and modern technology. The quest to shorter lengthscales, however, requires the use of light wavelengths beyond the visible. In particular, in the extreme ultraviolet regime these manipulation capabilities are hampered by the lack of efficient optics, especially for polarization control.

View Article and Find Full Text PDF

Spectroscopic Signatures of Phonon Character in Molecular Electron Spin Relaxation.

ACS Cent Sci

December 2024

Division of Chemistry and Chemical Engineering, Arthur Amos Noyes Laboratory of Chemical Physics, California Institute of Technology, Pasadena, California 91125, United States.

Spin-lattice relaxation constitutes a key challenge for the development of quantum technologies, as it destroys superpositions in molecular quantum bits (qubits) and magnetic memory in single molecule magnets (SMMs). Gaining mechanistic insight into the spin relaxation process has proven challenging owing to a lack of spectroscopic observables and contradictions among theoretical models. Here, we use pulse electron paramagnetic resonance (EPR) to profile changes in spin relaxation rates ( ) as a function of both temperature and magnetic field orientation, forming a two-dimensional data matrix.

View Article and Find Full Text PDF

To explore the value of high resolution computed tomography(HRCT) combined with Magnetic Resonance Imaging(MRI) in the diagnosis of inner ear malformation. HRCT and MRI data of 82 patients with inner ear malformations were analyzed retrospectively. HRCT MPR and CPR reconstruction of the inner ear structure, facial nerve canal and oblique sagittal MRI reconstruction of the internal auditory canal were performed.

View Article and Find Full Text PDF

Immediate breast reconstruction provides breast cancer patients with a valuable opportunity to restore breast shape. However, post-reconstruction breast asymmetry remains a common issue that affects patient satisfaction. This study aims to quantify breast asymmetry after surgery using magnetic resonance imaging (MRI) and assess its impact on both breast satisfaction and overall outcome satisfaction, offering scientific evidence to guide improvements in preoperative evaluation.

View Article and Find Full Text PDF

This work reports magnetic field direction dependent second magnetisation peak (SMP) anomaly in single crystals of oxygenated [Formula: see text] for [Formula: see text] ab. Detailed investigations on crystal A revealed the direction dependence of SMP anomaly at temperatures below 25 K, above which the direction dependence vanishes. The state of spatial order of the vortex lattice was found to be correlated to the vortex lattice symmetry that underwent a change at certain fields and was captured via single flux jumps observed in the third and fifth quadrant of magnetisation hysteresis loops.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!