Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Cardiopulmonary resuscitation (CPR) performed on a mattress decreases effective chest compression depth. Using a CPR board partially attenuates mattress compressibility. We aimed to determine the effect of a CPR board, a slider transfer board, a CPR board with a slider transfer board, and a flat spine board on chest compression depth with a mannequin placed on an emergency department mattress.
Methods: The study used a cross-over study design. The CPR-certified healthcare providers performed 2 minutes of compressions on a mannequin in five conditions, an emergency department mattress with: (a) no hard surface, (b) a CPR board, (c) a slider transfer board, (d) a CPR board and slider transfer board, and (e) a flat spine board. Compression depths were measured from two sources for each condition: (a) an internal device measuring sternum-to-spine compression and (b) an external device measuring sternum-to-spine compression plus mattress compression. The difference of the two measures (ie, depleted compression depth) was summarized and compared between conditions.
Results: A total of 10,203 individual compressions from 10 participants were analyzed. The mean depleted compression depths (percentage depletion) secondary to mattress effect were the following: 23.6 mm (29.7%) on a mattress only, 13.7 mm (19.5%) on a CPR board, 16.9 mm (23.1%) on a slider transfer board, 11.9 mm (17.3%) on a slider transfer board plus backboard, and 10.3 mm (15.4%) on a flat spine board. The differences in percentage depletion across conditions were statistically significant.
Conclusion: Cardiopulmonary resuscitation providers should use a CPR board and slider transfer board or a flat spine board alone because these conditions are associated with the smallest amount of mattress compressibility.