Variation in aluminium patch test reactivity over time.

Contact Dermatitis

Department of Occupational and Environmental Dermatology, Skåne University Hospital, Lund University, 205 02, Malmö, Sweden.

Published: November 2017

Background: Contact allergy to aluminium has been reported more frequently in recent years. It has been pointed out that positive patch test reactions to aluminium may not be reproducible on retesting.

Objectives: To investigate possible variations in patch test reactivity to aluminium over time.

Methods: Twenty-one adults, who had previously reacted positively to aluminium, were patch tested with equimolar dilution series in pet. of aluminium chloride hexahydrate and aluminium lactate, four times over a period of 8 months.

Results: Thirty-six of 84 (43%) serial dilution tests with aluminium chloride hexahydrate and 49 of 84 (58%) serial dilution tests with aluminium lactate gave negative results. The range of reactivity varied between a negative reaction to aluminium chloride hexahydrate at 10% and/or to aluminium lactate at 12%, and a positive reaction to aluminium chloride hexahydrate at 0.1% and/or to aluminium lactate at 0.12%. The highest individual difference in test reactivity noticed was 320-fold when the two most divergent minimal eliciting concentrations were compared.

Conclusions: The patch test reactivity to aluminium varies over time. Aluminium-allergic individuals may have false-negative reactions. Therefore, retesting with aluminium should be considered when there is a strong suspicion of aluminium contact allergy.

Download full-text PDF

Source
http://dx.doi.org/10.1111/cod.12836DOI Listing

Publication Analysis

Top Keywords

patch test
16
test reactivity
16
aluminium chloride
16
chloride hexahydrate
16
aluminium lactate
16
aluminium
15
aluminium patch
8
contact allergy
8
reactivity aluminium
8
serial dilution
8

Similar Publications

Deep Learning-Based Ion Channel Kinetics Analysis for Automated Patch Clamp Recording.

Adv Sci (Weinh)

December 2024

Department of Biomedical Engineering, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Kowloon, Hong Kong SAR, China.

The patch clamp technique is a fundamental tool for investigating ion channel dynamics and electrophysiological properties. This study proposes the first artificial intelligence framework for characterizing multiple ion channel kinetics of whole-cell recordings. The framework integrates machine learning for anomaly detection and deep learning for multi-class classification.

View Article and Find Full Text PDF

Immunoglobulin E (IgE)-mediated food allergy.

Allergy Asthma Clin Immunol

December 2024

Division of Allergy, Department of Pediatrics, Dalhousie University, IWK Health Centre, Halifax, NS, Canada.

Food allergy is defined as an adverse immunologic response to a food. Immunoglobulin E (IgE)-mediated reactions to foods are associated with a broad range of signs and symptoms that may involve any of the following body systems: the skin, gastrointestinal tract, respiratory tract, and cardiovascular system. IgE-mediated food allergy is a leading cause of anaphylaxis.

View Article and Find Full Text PDF

Polarization-sensitive optical coherence tomography (PS-OCT) measures the polarization state of backscattered light from tissues and provides valuable insights into the birefringence properties of biological tissues. Contrastive unpaired translation (CUT) was used in this study to generate a synthetic PS-OCT image from a single OCT image. The challenges related to extensive data requirements relying on labeled datasets using only pixel-wise correlations that make it difficult to efficiently regenerate the periodic patterns observed in PS-OCT images were addressed.

View Article and Find Full Text PDF

Background: In Amsterdam, a steep increase in positive reactions to propolis in the European baseline series was observed from 2.8% in 2020 to 16.4% in 2023.

View Article and Find Full Text PDF

Background: Sensitive skin causes discomfort from irritants, impacting quality of life. While hypoallergenic moisturizers help prevent moisture loss, some ingredients can still cause irritation. Treatments like steroids and calcineurin inhibitors have side effects, and chemical sunscreens can cause irritation in sensitive skin.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!