Reachability and the sense of embodiment in amputees using prostheses.

Sci Rep

Institute of Intelligent Systems and Robotics (ISIR), Sorbonne University, UPMC Univ Paris 06, CNRS, UMR 7222, INSERM U1150, Paris, France.

Published: July 2017

Amputated patients are hardly satisfied with upper limb prostheses, and tend to favour the use of their contralateral arm to partially compensate their disability. This may seem surprising in light of recent evidences that external objects (rubber hand or tool) can easily be embodied, namely incorporated in the body representation. We investigated both implicit body representations (by evaluating the peripersonal space using a reachability judgement task) and the quality of bodily integration of the patient's prosthesis (assessed via questionnaires). As expected, the patients estimated that they could reach further while wearing their prosthesis, showing an embodiment of their prosthesis in their judgement. Yet, the real reaching space was found to be smaller with their prosthesis than with their healthy limb, showing a large error between reachability judgement and actual capacity. An overestimation was also found on the healthy side (comparatively to healthy subjects) suggesting a bilateral modification of body representation in amputated patients. Finally, a correlation was found between the quality of integration of the prosthesis and the way the body representation changed. This study therefore illustrates the multifaceted nature of the phenomenon of prosthesis integration, which involves its incorporation as a tool, but also various specific subjective aspects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5503947PMC
http://dx.doi.org/10.1038/s41598-017-05094-6DOI Listing

Publication Analysis

Top Keywords

body representation
12
amputated patients
8
reachability judgement
8
prosthesis
6
reachability sense
4
sense embodiment
4
embodiment amputees
4
amputees prostheses
4
prostheses amputated
4
patients satisfied
4

Similar Publications

Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.

View Article and Find Full Text PDF

Morphologic study of patent ductus arteriosus based on computed tomography data in 25 dogs.

Front Vet Sci

December 2024

Department of Veterinary Clinical Science, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Republic of Korea.

Introduction: The objective of this study is to analyze the morphology and measurement dimensions of patent ductus arteriosus (PDA) based on computed tomography images.

Methods: The present study retrospectively evaluated computed tomography angiography data from 25 client-owned dogs diagnosed with PDA. PDA was reconstructed based on the central axis and the minimum diameter, ampulla diameter, angle, ampulla cross-section area, and length values were measured at specific measurement sites.

View Article and Find Full Text PDF

Multidimensional 3D-rendered objects are an important component of vision research and video- gaming applications, but it has remained challenging to parametrically control and efficiently generate those objects. Here, we describe a toolbox for controlling and efficiently generating 3D rendered objects composed of ten separate visual feature dimensions that can be fine-adjusted using python scripts. The toolbox defines objects as multi-dimensional feature vectors with primary dimensions (object body related features), secondary dimensions (head related features) and accessory dimensions (including arms, ears, or beaks).

View Article and Find Full Text PDF

Objectives: Radiotherapy manages pancreatic cancer in various settings; however, the proximity of gastrointestinal (GI) luminal organs-at-risk (OAR) poses challenges to conventional radiotherapy. Proton beam therapy (PBT) may reduce toxicities compared to photon therapy. This consensus statement summarizes PBT's safe and optimal delivery for pancreatic tumors.

View Article and Find Full Text PDF

Study Question: Are empirically derived adolescent overweight/obesity phenotypes differentially associated with polycystic ovary syndrome (PCOS) in young adulthood?

Summary Answer: Self-reported PCOS diagnosis risk in young adulthood varied by empirically derived adolescent overweight/obesity phenotypes, with the highest risk observed among those in the 'mothers with obesity' and 'early puberty' phenotypes.

What Is Known Already: Overweight and obesity during puberty are postulated to promote the development of PCOS. Much of the prior literature in this area is cross-sectional and defines weight status based solely on BMI, yet emerging research suggests that not all people with overweight/obesity have the same risk for chronic health conditions, including PCOS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!