A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Polyurethane versus silicone port a cath: What's going on at removal? | LitMetric

Polyurethane versus silicone port a cath: What's going on at removal?

J Pediatr Surg

Pediatric Surgery Unit, Hospital Universitary Center of Tours, Gatien de Clocheville Hospital, 37000 Tours, France. Electronic address:

Published: July 2018

Background: Port-a-cath (PAC) is an essential device in the management of the patients of chronic illness, but despite theirs benefits there are many complications either at the time of insertion or at time of removal. Our aim of this study is to evaluate the fracture rate of the catheter at removal time in comparison with catheter type either polyurethane or silicone.

Methods: A retrospective monocentric study of all PACs which were removed at our university pediatric hospital between 1 January 2006 and 31 December 2016. Two groups were compared: polyurethane group and silicone group.

Results: Total of 216 central lines were removed, the mean age at the time of extraction was 9.7±4.9years and the mean time for both catheter was 2.7±1.6years, fracture occurred in 11 catheter of the polyurethane group (n=119), with no fracture of silicone group (n=86), in the polyurethane group, the risk of catheter fracture is significantly related to the duration of the PAC in place.

Conclusion: We found that the polyurethane-based catheters are more vulnerable for rupture and retained fragment in the blood vessels, especially if left in place for long time, for this reason we have switched to silicone-based catheter and all catheters should be remove within duration maximal of 2years.

Type Of Study: Prognosis study.

Level Of Evidence: Level II.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpedsurg.2017.06.025DOI Listing

Publication Analysis

Top Keywords

polyurethane group
12
time
6
catheter
6
polyurethane
5
polyurethane versus
4
versus silicone
4
silicone port
4
port cath
4
cath what's
4
what's going
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!