Purpose: The aim of this study was to assess the diagnostic performance of simultaneous whole-body Ga-DOTANOC PET/MRI compared with Ga-DOTANOC PET/CT for detection of distant metastatic disease in patients with well-differentiated neuroendocrine tumors (NETs).
Methods: Patients with histologically proven, well-differentiated NET (G1 or G2) were included in this prospective, institutional review board-approved study. Patients underwent Ga-DOTANOC PET/CT and subsequent Ga-DOTANOC PET/MRI after a single tracer injection on the same day for staging or restaging purposes. Images were evaluated for the presence of NET lesions by 2 rater teams, each consisting of a nuclear medicine physician and a radiologist, in an observer-blinded fashion. Overall agreement, accuracy, sensitivity, and specificity, relative to a composite reference standard (consensus review including follow-up data), were calculated.
Results: Between July 2014 and June 2016, 28 patients were enrolled. Overall agreement and accuracy between the 2 rater teams were 91.7% (95% confidence interval [CI], 87.5%-95.9%) and 97% (95% CI, 94.4%-99.6%) for PET/MRI and 92.3% (95% CI, 88.3%-96.3%) and 94.6% (95% CI, 91.2%-98.1%) for PET/CT, respectively (P = 1.00).Overall, PET/MRI reached 89.8% sensitivity (95% CI, 77.8%-96.6%) and 100% specificity (95% CI, 97%-100%); PET/CT showed 81.6% sensitivity (95% CI, 68%-91.2%) and 100% specificity (95% CI, 97%-100%) for the detection of metastatic disease in NETs.
Conclusions: Whole-body Ga-DOTANOC PET/MRI appears to be comparable to Ga-DOTANOC PET/CT for lesion detection in patients with well-differentiated NETs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5636054 | PMC |
http://dx.doi.org/10.1097/RLU.0000000000001753 | DOI Listing |
Eur J Nucl Med Mol Imaging
January 2020
Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria.
Purpose: PET/MRI has recently been introduced into clinical practice. We prospectively investigated the clinical impact of PET/MRI compared with PET/CT, in a mixed population of cancer patients, and performed an economic evaluation of PET/MRI.
Methods: Cancer patients referred for routine staging or follow-up by PET/CT underwent consecutive PET/CT and PET/MRI, using single applications of [F]FDG, [Ga]Ga-DOTANOC, or [F]FDOPA, depending on tumor histology.
Clin Nucl Med
September 2017
From the Divisions of *General and Pediatric Radiology and †Nuclear Medicine, Department of Biomedical Imaging and Image-Guided Therapy, and ‡Department of Internal Medicine I, Medical University of Vienna, Vienna, Austria.
Purpose: The aim of this study was to assess the diagnostic performance of simultaneous whole-body Ga-DOTANOC PET/MRI compared with Ga-DOTANOC PET/CT for detection of distant metastatic disease in patients with well-differentiated neuroendocrine tumors (NETs).
Methods: Patients with histologically proven, well-differentiated NET (G1 or G2) were included in this prospective, institutional review board-approved study. Patients underwent Ga-DOTANOC PET/CT and subsequent Ga-DOTANOC PET/MRI after a single tracer injection on the same day for staging or restaging purposes.
J Nucl Med
September 2017
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.
The aim of this study was to compare attenuation-correction (AC) approaches for PET/MRI in clinical neurooncology. Forty-nine PET/MRI brain scans were included: brain tumor studies using F-fluoro-ethyl-tyrosine (F-FET) ( = 31) and Ga-DOTANOC ( = 7) and studies of healthy subjects using F-FDG ( = 11). For each subject, MR-based AC maps (MR-AC) were acquired using the standard DIXON- and ultrashort echo time (UTE)-based approaches.