A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the use of unipolar voltage amplitudes for detection of myocardial scar assessed by cardiac magnetic resonance imaging in heart failure patients. | LitMetric

Background: Validation of voltage-based scar delineation has been limited to small populations using mainly endocardial measurements. The aim of this study is to compare unipolar voltage amplitudes (UnipV) with scar on delayed enhancement cardiac magnetic resonance imaging (DE-CMR).

Methods: Heart failure patients who underwent DE-CMR and electro-anatomic mapping were included. Thirty-three endocardial mapped patients and 27 epicardial mapped patients were investigated. UnipV were computed peak-to-peak. Electrograms were matched with scar extent of the corresponding DE-CMR segment using a 16-segment/slice model. Non-scar was defined as 0% scar, while scar was defined as 1-100% scar extent.

Results: UnipVs were moderately lower in scar than in non-scar (endocardial 7.1 [4.6-10.6] vs. 10.3 [7.4-14.2] mV; epicardial 6.7 [3.6-10.5] vs. 7.8 [4.2-12.3] mV; both p<0.001). The correlation between UnipV and scar extent was moderate for endocardial (R = -0.33, p<0.001), and poor for epicardial measurements (R = -0.07, p<0.001). Endocardial UnipV predicted segments with >25%, >50% and >75% scar extent with AUCs of 0.72, 0.73 and 0.76, respectively, while epicardial UnipV were poor scar predictors, independent of scar burden (AUC = 0.47-0.56). UnipV in non-scar varied widely between patients (p<0.001) and were lower in scar compared to non-scar in only 9/22 (41%) endocardial mapped patients and 4/19 (21%) epicardial mapped patients with scar.

Conclusion: UnipV are slightly lower in scar compared to non-scar. However, significant UnipV differences between and within patients and large overlap between non-scar and scar limits the reliability of accurate scar assessment, especially in epicardial measurements and in segments with less than 75% scar extent.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5498065PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0180637PLOS

Publication Analysis

Top Keywords

scar
11
unipolar voltage
8
voltage amplitudes
8
cardiac magnetic
8
magnetic resonance
8
resonance imaging
8
heart failure
8
failure patients
8
mapped patients
8
scar extent
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!