Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Most idiopathic ventricular arrhythmias (VAs) originate from the outflow tracts and are characterized by an inferior axis on the 12-lead ECG. A group of patients will exhibit inferior lead discordance (ILD), demonstrating a positive QRS in lead II with negative QRS in III or the opposite finding.
Methods And Results: We identified patients undergoing ablation of idiopathic premature ventricular contractions (PVCs) or ventricular tachycardia (VT) between 2013 and 2015. The site of earliest activation was determined using electroanatomic mapping and intracardiac echocardiography. Out of 281 patients, 25 (8.9%) exhibited ILD. In patients with positive/negative discordance (n = 18), the source was mapped to the parahisian region in 14 cases and to the right ventricular (RV) moderator band (MB) or papillary muscles (PMs) in 4, while all those with negative/positive discordance (n = 7) were mapped to the anterolateral PM (ALPM). In the group with positive/negative discordance, a later precordial transition (>V4), wider QRS duration, and the presence of notch in the inferior leads pointed toward a RV MB/PM origin. Complete PVC/VT suppression was achieved in 72%. In 2 patients with parahisian PVCs, ablation was not attempted due to risk of heart block.
Conclusions: The presence of ILD is associated with particular anatomical locations, namely, the parahisian region, RV MB/PM, and ALPM. The outcomes of ablation are more modest compared to other idiopathic VAs, reflecting the technical difficulties associated with these anatomical locations, such as the proximity to the conduction system in parahisian VAs or stability issues when ablating the PMs or MB.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/jce.13287 | DOI Listing |