Purpose: To evaluate the diagnostic performance of dual-energy computed tomography (DECT) for the assessment of myocardial viability compared with magnetic resonance imaging (MRI) in patients with chronic myocardial infarction (CMI).
Methods And Material: Twenty-six patients were prospectively enrolled, who underwent DECT and MRI at delayed phase. The infarct volumes for DECT and MRI were measured.
Results: In per-segment and per-vessel analysis, DECT showed excellent diagnostic performance compared with MRI (diagnostic accuracy: 86.2%, 81.2% respectively). In volume analysis, DECT correlated well with MRI (r=0.966, p<0.0001).
Conclusions: DECT has excellent diagnostic performance for detecting CMI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clinimag.2017.06.003 | DOI Listing |
Am Heart J Plus
January 2025
University of Pittsburgh Medical Center, Pittsburgh, PA, United States of America.
Objective: Evaluate the relationship of cathepsin-D (CD) on disease severity and clinical outcomes for women with peripartum cardiomyopathy.
Background: Cathepsin-D is a protease released during oxidative stress that cleaves prolactin (PRL) generating a 16 kDa fragment that is pro-apoptotic, anti-angiogenic, and has been implicated in the pathogenesis of peripartum cardiomyopathy (PPCM).
Methods: In 99 women with newly diagnosed PPCM enrolled in the Investigation in Pregnancy Associated Cardiomyopathy (IPAC) study, CD levels were assessed by ELISA from serum obtained at study entry.
Eur J Radiol Open
June 2025
Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No.218 Jixi Road, Hefei, Anhui 230022, China.
Objectives: Subclinical myocardial involvement is common in systemic lupus erythematosus (SLE), but differences between new onset and longstanding SLE are not fully elucidated. This study compared myocardial involvement in new onset versus longstanding SLE using cardiovascular magnetic resonance (CMR).
Materials And Methods: We prospectively enrolled 24 drug-naïve new onset SLE patients, 27 longstanding SLE patients, and 20 healthy controls.
Lancet Reg Health Southeast Asia
January 2025
British Heart Foundation Cardiovascular Epidemiology Unit, Department of Public Health and Primary Care, University of Cambridge, Cambridge, UK.
Background: South Asians may be particularly susceptible to premature myocardial infarction (MI) owing both to conventional cardiovascular risk factors and practices distinctive to South Asia. Identifying modifiable risk factors for MI in these populations could inform prevention strategies. We have, therefore, studied conventional risk factors and other characteristics in relation to occurrence of first MI in Bangladesh.
View Article and Find Full Text PDFEur Heart J Imaging Methods Pract
January 2025
Student Research Committee, Shiraz University of Medical Sciences, Shiraz, Iran.
Aims: While most clinical guidelines recommend using a 64-projection view technique, some protocols do not specify a preference between 32-projection and 64-projection methods for conducting myocardial perfusion scintigraphy (MPS), which shows the lack of consensus in this matter. Nevertheless, these guidelines and protocols have not provided us with compelling evidence to support why the 64-projection technique is usually chosen. Thus, we aimed to determine if there is a significant difference between them in the assessment of cardiac perfusion and functional indices.
View Article and Find Full Text PDFEur Heart J Imaging Methods Pract
January 2025
A.I. Virtanen Institute, University of Eastern Finland, Neulaniementie 2, 70210 Kuopio, Finland.
Aims: The aim of this study was to develop an ultra-short echo time 3D magnetic resonance imaging (MRI) method for imaging subacute myocardial infarction (MI) quantitatively and in an accelerated way. Here, we present novel 3D T- and T -weighted Multi-Band SWeep Imaging with Fourier Transform and Compressed Sensing (MB-SWIFT-CS) imaging of subacute MI in mice hearts .
Methods And Results: Relaxation time-weighted and under-sampled 3D MB-SWIFT-CS MRI were tested with manganese chloride (MnCl) phantom and mice MI model.