Health impact of metal mixture at environment realistic concentrations are difficult to predict especially for long-term effects where cause-and-effect relationships may not be directly obvious. This study was aimed to evaluate metal mixture (Zn-0.1, Cu-0.01, Ni-0.01, Cr-0.01, Pb-0.005 and Cd-0.005 mg/L, respectively for 1, 2, 4, 7, 14 and 28 days at concentrations accepted for the inland waters in EU) genotoxicity (micronuclei, nuclear buds, nuclear buds on filament), cytotoxicity (8-shaped nuclei, fragmented-apoptotic erythrocytes), bioaccumulation, steady-state and the reference level of geno-cytotoxicity in hatchery-reared Atlantic salmon tissues. Metals accumulated mostly in gills and kidneys, to the lesser extent in the muscle. Uptake of metals from an entire mixture in the fish for 14 days is sufficient to reach steady-state Cr, Pb concentrations in all tissues; Zn, Cu-in kidneys and muscle, Ni-in liver, kidneys, muscle and Cd-in muscle. Treatment with metal mixture significantly increased summed genotoxicity levels at 7 days of exposure in peripheral blood and liver erythrocytes, at 14 days of exposure in gills and kidney erythrocytes. Significant elevation of cytotoxicity was detected after 2 and 14 days of exposure in gills erythrocytes and after 28 days-in peripheral blood erythrocytes. The amount of Cu, Cr, Pb and Cd accumulated in tissues was dependent upon duration of exposure; nuclear buds, 8-shaped nuclei frequencies also were dependent upon duration of exposure. This study indicates that metals at low levels when existing in mixture causes significant geno-cytotoxicity responses and metals bioaccumulation in salmon.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10646-017-1833-0 | DOI Listing |
J Phys Chem A
January 2025
Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, United States.
When dielectrics are hit with intense infrared (IR) laser pulses, transient metalization can occur. The initial attosecond dynamics behind this metallization are not entirely understood. Therefore, simulations are needed to understand this process and to help interpret experimental observations of it, such as with attosecond transient absorption (ATA).
View Article and Find Full Text PDFBiol Trace Elem Res
January 2025
Department of Geriatrics, The Second Affiliated Hospital, Nanjing Medical University, Nanjing, 210011, China.
Several studies have reported associations between specific heavy metals and essential trace elements and acute myocardial infarction (AMI). However, there is limited understanding of the relationships between trace elements and AMI in real-life co-exposure scenarios, where multiple elements may interact simultaneously. This cross-sectional study measured serum levels of 56 trace elements using inductively coupled plasma mass spectrometry.
View Article and Find Full Text PDFChem Asian J
January 2025
Indian Institute of Technology Guwahati, Department of Chemistry, Department of Chemistry, 781039, Guwahati, INDIA.
Fulfilment of energy demand by utilizing renewable energy sources that do not contribute to the production of greenhouse gases is a step forward in mitigating global warming. However, with the energy sources being intermittent in nature, renewable energy needs to be stored effectively on a grid scale. In this context, the development of redox-flow batteries has emerged as a promising technology where charging and discharging processes are accomplished by the redox shuttling of the electrolytes, namely anolytes and catholytes.
View Article and Find Full Text PDFChem Asian J
January 2025
Shenzhen Polytechnic University, Hoffmann Institute of Advanced Materials, 7098 Liuxian Blvd., 518055, Shenzhen, CHINA.
The purification of polymer-grade (>99.9%) olefins (mostly C2 and C3) represents a significant yet challenging process in petrochemical industry. The commonly employed method for hydrocarbon separation involves heat-driven distillations.
View Article and Find Full Text PDFAppl Radiat Isot
January 2025
Tokyo City University, 1-28-1, Tamazutsumi, Setagaya-ku, Tokyo, 158-8557, Japan.
In clearance measurements involving a single material type, a conversion factor was applied to convert measurement results to activity based on an assumed uniform density. However, this factor has been found to underestimate activity in material mixtures. In this study, we proposed a method to identify the location with the lowest detection sensitivity (minimum location) in a mixture and evaluated its applicability to the conversion factor.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!