A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Physiologic musculofascial compliance following reinforcement with electrospun polycaprolactone-ureidopyrimidinone mesh in a rat model. | LitMetric

Physiologic musculofascial compliance following reinforcement with electrospun polycaprolactone-ureidopyrimidinone mesh in a rat model.

J Mech Behav Biomed Mater

Centre for Surgical Technologies, KU Leuven, Leuven, Belgium; Department of Development and Regeneration, KU Leuven, Leuven, Belgium; Pelvic Floor Unit, University Hospitals KU Leuven, Leuven, Belgium. Electronic address:

Published: October 2017

Purpose: Electrospun meshes may be considered as substitutes to textile polypropylene implants. We compared the host response and biomechanical properties of the rat abdominal wall following reinforcement with either polycaprolactone (PCL) modified with ureidopyrimidinone-motifs (UPy) or polypropylene mesh.

Methods: First we measured the response to cyclic uniaxial load within the physiological range both dry (room temperature) and wet (body temperature). 36 rats underwent primary repair of a full-thickness abdominal wall defect with a polypropylene suture (native tissue repair), or reinforced with either UPy-PCL or ultra-light weight polypropylene mesh (n = 12/group). Sacrifice was at 7 and 42 days. Outcomes were compliance of explants, mesh dimensions, graft related complications and semi-quantitative assessment of inflammatory cell (sub) types, neovascularization and remodeling.

Results: Dry UPy-PCL implants are less stiff than polypropylene, both are more compliant in wet conditions. Polypropylene loses stiffness on cyclic loading. Both implant types were well incorporated without clinically obvious degradation or herniation. Exposure rates were similar (n = 2/12) as well as mesh contraction. There was no reinforcement at low loads, while, at higher tension, polypropylene explants were much stiffer than UPy-PCL. The latter was initially weaker yet by 42 days it had a compliance similar to native abdominal wall. There were eventually more foreign body giant cells around UPy-PCL fibers yet the amount of M1 subtype macrophages was higher than in polypropylene explants. There were less neovascularization and collagen deposition.

Conclusion: Abdominal wall reconstruction with electrospun UPy-PCL mesh does not compromise physiologic tissue biomechanical properties, yet provokes a vivid inflammatory reaction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2017.06.032DOI Listing

Publication Analysis

Top Keywords

abdominal wall
16
polypropylene
8
biomechanical properties
8
polypropylene explants
8
mesh
5
upy-pcl
5
physiologic musculofascial
4
musculofascial compliance
4
compliance reinforcement
4
reinforcement electrospun
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!