How does the use of multiple needles/syringes per injecting episode impact on the measurement of individual level needle and syringe program coverage?

Int J Drug Policy

Centre for Population Health, Burnet Institute, 85 Commercial Rd, Melbourne, VIC 3004, Australia; School of Public Health and Preventive Medicine, Monash University, 99 Commercial Rd, Melbourne, VIC 3004, Australia. Electronic address:

Published: August 2017

Background: Recent work by McCormack et al. (2016) showed that the inclusion of syringe stockpiling improves the measurement of individual-level syringe coverage. We explored whether including the use of a new parameter, multiple sterile syringes per injecting episode, further improves coverage measures.

Methods: Data comes from 838 people who inject drugs, interviewed as part of the 2015 Illicit Drug Reporting System. Along with syringe coverage questions, the survey recorded the number of sterile syringes used on average per injecting episode. We constructed three measures of coverage: one adapted from Bluthenthal et al. (2007), the McCormack et al. measure, and a new coverage measure that included use of multiple syringes. Predictors of multiple syringe use and insufficient coverage (<100% of injecting episodes using a sterile syringe) using the new measure, were tested in logistic regression and the ability of the measures to discriminate key risk behaviours was compared using ROC curve analysis.

Results: 134 (16%) participants reported needing multiple syringes per injecting episode. Women showed significantly increased odds of multiple syringe use, as did those reporting injection related injuries/diseases and injecting of opioid substitution drugs or pharmaceutical opioids. Levels of insufficient coverage across the three measures were substantial (20%-28%). ROC curve analysis suggested that our new measure was no better at discriminating injecting risk behaviours than the existing measures.

Conclusion: Based on our findings, there appears to be little need for adding a multiple syringe use parameter to existing coverage formulae. Hence, we recommend that multiple syringe use is not included in the measurement of individual-level syringe coverage.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.drugpo.2017.05.055DOI Listing

Publication Analysis

Top Keywords

injecting episode
12
syringe coverage
8
sterile syringes
8
coverage
6
syringe
5
multiple
4
multiple needles/syringes
4
needles/syringes injecting
4
episode impact
4
impact measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!