Calibration and validation processes for relative humidity measurement by a Hygrochron iButton.

Physiol Behav

Exercise, Heath & Performance Research Group, Faculty of Health Sciences, The University of Sydney, Australia.

Published: October 2017

Accurate relative humidity (RH) measurement is demanded in studies of thermal comfort. Thermal discomfort occurs when the near-to-skin temperature or RH is outside of the thermal comfort zone. The Hygrochron, a small wireless device which measures both temperature and RH, would be suitable and convenient in exercise or sleep studies. However, the RH measurement has not been validated. This paper has three parts. Part 1: In evaluating the sensor surface for RH detection, four Hygrochrons were placed on a wet paper towel. Two were placed on the towel with the protruding surface facing up and the other two facing down. The results showed that the Hygrochron with the protruding side was the sensor surface for detecting RH. Part 2: Twenty-seven Hygrochrons were calibrated in a humidity calibration chamber at a RH range from 40 to 90% at a constant temperature from 32 to 37°C. The mean bias was -1.08% between the Hygrochrons and the calibration chamber. The Hygrochron overestimated RH at the lower range (40-60%) and underestimated RH at the higher range (80-90%). The application of individual regression equations to each Hygrochron improved accuracy and reduced the mean bias to -0.002%. However, one Hygrochron showed outlier values that may be due to a manufacturing defect. Part 3: The reproducibility of Hygrochron for RH measurements was tested twice at the same condition of 35°C over a three-month interval. The intra-class coefficient was 0.996 to 1.000 with non-significant differences in the mean RH between test and re-test results (p=0.159). Hygrochrons are valid for RH measurements which show high reproducibility. It is recommended that Hygrochrons be calibrated over a range of desired RH and temperature prior to use to improve accuracy and detect any manufacturing defects.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.physbeh.2017.06.019DOI Listing

Publication Analysis

Top Keywords

relative humidity
8
humidity measurement
8
thermal comfort
8
sensor surface
8
hygrochrons calibrated
8
calibration chamber
8
hygrochron
7
hygrochrons
5
calibration validation
4
validation processes
4

Similar Publications

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

Drug-drug co-amorphous systems are a promising approach to improve the aqueous solubility of poorly water-soluble drugs. This study explores the combination of breviscapine (BRE) and matrine (MAT) form an amorphous salt, aiming to synergistically enhance the solubility and dissolution of BRE. In silico analysis of electrostatic potential and local ionization energy were conducted on BRE-MAT complex to predict the intermolecular interactions, and solvent-free energies were calculated using thermodynamic integration and density functional theory.

View Article and Find Full Text PDF

Agriculture 4.0 technologies continue to see low adoption among small and medium-sized farmers, primarily because these solutions often fail to account for the specific challenges of rural areas. In this work, we propose and implement a design methodology to develop a Precision Agriculture solution aimed at assisting farmers in managing water stress in Hass avocado crops.

View Article and Find Full Text PDF

The present study examined the effects of breeder age and oxygen (O₂) concentrations during the late chorioallantoic membrane (CAM) growth stage on embryo development, hatching dynamics, chick quality, bone mineralization and hatchability. A total of 1200 eggs from 33- and 50-week-old ISA layer breeders, weighing 53.85 g and 60.

View Article and Find Full Text PDF

Humidity sensors have been widely used to monitor humidity in daily life, agriculture fields, and so on. However, conventional sensors are not suitable for wearable devices because of their large dimensions and rigid substrates. Hence, we report a fast response, highly sensitive, and fully flexible humidity sensor on a PI substrate based on the composite material of reduced graphene oxide (rGO)/MoS, with a response time of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!