Prognostic value of a faster, low-radiation myocardial perfusion SPECT protocol in a CZT camera.

Int J Cardiovasc Imaging

Clinica de Diagnóstico por Imagem, Av. Ataulfo de Paiva 669, Leblon, Rio de Janeiro, RJ, Brazil.

Published: December 2017

To determine the prognostic value of a new, ultrafast, low dose myocardial perfusion SPECT (MPS) protocol in a cadmium-zinc telluride (CZT) camera. CZT cameras have introduced significant progress in MPS imaging, offering high-quality images despite lower doses and scan time. Yet, it is unknown if, with such protocol changes, the prognostic value of MPS is preserved. Patients had a 1-day 99 m-Tc-sestamibi protocol, starting with the rest (185-222 MBq) followed by stress (666-740 MBq). Acquisition times were 6 and 3 min, respectively. MPS were classified as normal or abnormal perfusion scans and summed scores of stress, rest, and difference (SSS, SRS and SDS), calculated. Patients were followed with 6-month phone calls. Hard events were defined as death or nonfatal myocardial infarction. Late revascularization was that occurring after 60 days of MPS. 2930 patients (age 64.0 ± 12.1 years, 53.3% male) were followed for 30.7 ± 7.5 months. Mean dosimetry was 6 mSv and mean total study time, 48 ± 13 min. The annual hard event and late revascularization rate were higher in patients with greater extension of defect and ischemia. SSS was higher in patients with hard events compared to those without events (2.6 ± 4.9 vs. 5.0 ± 6.3, p < 0.001), as well as the SDS (0.7 ± 1.9 vs. 1.7 ± 3.4, p < 0.00). The same was true for patients with or without late revascularization (SSS: 2.5 ± 4.7 vs. 6.6 ± 7.1; SDS: 0.6 ± 1.7 vs. 2.9 ± 3.8, p < 0.01). A new, faster, low-radiation, MPS protocol in a CZT camera maintain the ability to stratify patients with increased risk of events, showing that, in the presence of greater extension of defect or ischemia, patients presented higher rates of hard events and late revascularization.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-017-1202-3DOI Listing

Publication Analysis

Top Keywords

myocardial perfusion
8
perfusion spect
8
czt camera
8
hard events
8
late revascularization
8
higher patients
8
mps
5
patients
5
prognostic faster
4
faster low-radiation
4

Similar Publications

The Relationship Between Quantitative Ischemia, Early Revascularization, and Major Adverse Cardiovascular Events: A Multicenter Study.

JACC Adv

January 2025

Department of Medicine (Division of Artificial Intelligence in Medicine), Biomedical Sciences, and Imaging, Cedars-Sinai Medical Center, Los Angeles, California, United States.

Background: Observational data have suggested that patients with moderate to severe ischemia benefit from revascularization. However, this was not confirmed in a large, randomized trial.

Objectives: Using a contemporary, multicenter registry, the authors evaluated differences in the association between quantitative ischemia, revascularization, and outcomes across important subgroups.

View Article and Find Full Text PDF

The cardioprotective effects of HTK solution and conventional blood cardioplegia in patients with atrial fibrillation undergoing valvular replacement and Cox maze III procedure.

J Cardiothorac Surg

January 2025

Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Women and Children's Healthcare Hospital, No. 123, Tianfei Lane, Mochou Road, Nanjing, Jiangsu, 210004, China.

Introduction: The study was to assess the myocardial protection effects of the histidine-tryptophan-ketoglutarate (HTK) solution and the 4:1 blood cardioplegia (BC) in patients with atrial fibrillation (AF) who were subjected to valvular replacement concomitant with the Cox maze III surgery.

Methods: A cohort of 148 individuals afflicted with AF, who received valve replacement surgery in conjunction with the Cox maze III procedure at our clinic within the period extending from 2015 to 2023, were enrolled. Subsequent to adjustment by propensity score matching (PSM), the patients were categorized into two distinct groups: the HTK group and the BC group.

View Article and Find Full Text PDF

Assessment of Coronary Microcirculation with High Frame-Rate Contrast-Enhanced Echocardiography.

Ultrasound Med Biol

January 2025

Biomedical Engineering, Cardiology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands; Medical Imaging, Department of Imaging Physics, Faculty of Applied Sciences, Delft University of Technology, Delft, the Netherlands. Electronic address:

Objective: Assessing myocardial perfusion in acute myocardial infarction is important for guiding clinicians in choosing appropriate treatment strategies. Echocardiography can be used due to its direct feedback and bedside nature, but it currently faces image quality issues and an inability to differentiate coronary macro- from micro-circulation. We previously developed an imaging scheme using high frame-rate contrast-enhanced ultrasound (HFR CEUS) with higher order singular value decomposition (HOSVD) that provides dynamic perfusion and vascular flow visualization.

View Article and Find Full Text PDF

Robust preclinical models of asymmetric ventricular loading in late gestation reflecting conditions such as hypoplastic left heart syndrome are lacking. We characterized the morphometry and microvascular function of the hypoplastic left ventricle (LV) and remaining right ventricle (RV) in a sham-controlled late gestation fetal lamb model of impaired left ventricular inflow (ILVI). Singleton fetuses were instrumented at ∼120 days gestational age (dGA; term is ∼147 days) with vascular catheters, an aortic flow probe and a deflated left atrial balloon.

View Article and Find Full Text PDF

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!