Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Objectives: Endoscopic ultrasound-guided biliary drainage (EUS-BD), first reported as an alternative to percutaneous transhepatic BD in failed endoscopic retrograde cholangiography, is sometimes performed as reintervention for transpapillary stent dysfunction such as in patients with new onset gastric outlet obstruction, but direct conversion to EUS-BD can potentially have a risk of leakage of infected bile. The aim of this study is to evaluate the safety and efficacy of conversion to EUS-BD using a temporary endoscopic nasobiliary drainage (ENBD) tube placement as a reintervention for prior BD.
Patients And Methods: Sixteen patients with prior BD for malignant biliary obstruction undergoing conversion to EUS-BD using a temporary ENBD tube placement were studied. Technical and clinical success rate and adverse events were evaluated.
Results: The major reason for conversion to EUS-BD was recurrent cholangitis due to duodenobiliary reflux (n = 13). In 14 patients with an indwelling covered metal or plastic stent, the stents were removed before temporary ENBD placement. After a median duration of 6 days, subsequent conversion to EUS-BD using a covered metal stent was performed, which was technically and clinically successful in all 16 patients (14 hepaticogastrostomy and 2 choledochoduodenostomy). Adverse events were observed in 3 patients (19%): one bleeding, one cholecystitis, and one cholangitis. No bile leak, peritonitis, or sepsis was observed.
Conclusions: Conversion to EUS-BD using temporary ENBD tube placement in patients with prior BD was technically feasible and relatively safe without infectious complications related to bile leakage.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5664853 | PMC |
http://dx.doi.org/10.4103/2303-9027.199763 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!