Objective: This study investigated the influence of the aortic bifurcation anatomy on the endovascular treatment of abdominal aortic aneurysms using Excluder (W. L. Gore & Associates, Flagstaff, Ariz) bifurcated stent grafts.

Methods: This was a retrospective single-center study of patients treated with the Excluder stent graft. Analysis included anatomical factors of the aortic bifurcation (aortic bifurcation diameter [ABD], calcification, thrombus), characteristics of the stent graft limbs (sum of stent graft limbs diameters [SLD]), and the SLD/ABD ratio. Narrow bifurcation was defined as ABD <20 mm. Primary outcomes were intraoperative stenosis, need for additional intraoperative measures, limb stenosis, and occlusion during follow-up.

Results: The study included 232 patients. Mean ABD was 24.6 ± 6 mm, with 53 patients (23%) presenting with narrow bifurcation (range, 12.5-19.5 mm). Median SLD in these patients was 28 mm, and the SLD/ABD ratio was 1.64. Calcification involving >50% of the bifurcation circumference was present in 32% of the patients, with 17% presenting thrombus in this area. Of 53 patients with narrow bifurcation, intraoperative stenosis >50% occurred in three (5.7%), which required adjunctive treatment. Computed tomography at 1 month showed limb stenosis >50% in nine patients (17%). No limb occlusions were recorded with a median follow-up of 34 months. Multivariate analysis of the overall series showed a higher risk of limb stenosis on the computed tomography at 1 month in patients with peripheral artery disease (hazard ratio [HR], 5.3; 95% confidence interval [CI], 1.2-24.4; P = .032), narrow bifurcation (HR, 5.7; 95% CI, 2-15.8; P = .001), higher SLD/ABD ratio (HR, 29.3; 95% CI, 4-215.2; P = .001), and calcium >50% (HR, 3; 95% CI, 1.1-8; P = .03), and lower in bifurcations with thrombus (HR, 0.3; 95% CI, 0.1-0.8; P = .017).

Conclusions: Abdominal aortic aneurysms with narrow bifurcation can be treated with the bifurcated Excluder device without additional adjunctive measures. The presence of limb stenosis during follow-up is not associated with occlusion. Long-term follow-up studies are needed to confirm these results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2017.04.065DOI Listing

Publication Analysis

Top Keywords

aortic bifurcation
16
narrow bifurcation
16
abdominal aortic
12
aortic aneurysms
12
stent graft
12
limb stenosis
12
bifurcation
9
endovascular treatment
8
treatment abdominal
8
aneurysms narrow
8

Similar Publications

Background: Current guidelines recommend preserving at least one of the bilateral pelvic flows in patients with aortoiliac aneurysms. The sandwich parallel graft, using commercially available devices, provides a viable option for patients who fall outside the instructions for use of iliac branch devices. However, gutter endoleak remains a significant challenge.

View Article and Find Full Text PDF

Persistent trigeminal artery variant as a duplicate anterior inferior cerebellar artery.

Surg Radiol Anat

December 2024

Department of Neurosurgery, Nakamura Memorial Hospital, South 1, West 14, Chuo-ku, Sapporo, 060-8570, Hokkaido, Japan.

Purpose: A persistent trigeminal artery is the most common persistent carotid-vertebrobasilar anastomosis. Persistent trigeminal artery variants (PTAVs) terminate in the cerebellar arteries without connecting to the basilar artery; of these, the anterior inferior cerebellar artery (AICA) is the most common. AICA duplication is frequently observed.

View Article and Find Full Text PDF

Objective: This study offers a retrospective assessment of a single-center experience using cerebrospinal fluid catheters to reduce the risk of perioperative spinal cord injury in patients undergoing single-staged complex endovascular juxtarenal or thoracoabdominal aortic aneurysm repair.

Results: A total of 97 patients were included. On average, 70.

View Article and Find Full Text PDF

Modeling fibrous tissue for vascular fluid-structure interaction analysis poses significant challenges due to the lack of effective tools for preparing simulation data from medical images. This limitation hinders the physiologically realistic modeling of vasculature and its use in clinical settings. Leveraging an established lumen modeling strategy, we propose a comprehensive pipeline for generating thick-walled artery models.

View Article and Find Full Text PDF

Acute thrombosis of ductus arteriosus aneurysm causing bilateral pulmonary artery occlusion in a neonate.

J Cardiothorac Surg

December 2024

Department of congenital heart surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong Province, China.

A 9-day-old male neonate was found to have a systolic murmur during a routine follow-up for skin jaundice. Imaging revealed a large mass at the bifurcation of the main pulmonary artery, causing significant bilateral stenosis. The patient underwent emergency surgery due to critically compromised pulmonary blood flow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!