Von Willebrand's disease (VWD) is the most common inherited bleeding disorder caused by either quantitative or qualitative defects of von Willebrand factor (VWF). Current tests for VWD require relatively large blood volumes, have low throughput, are time-consuming, and do not incorporate the physiologically relevant effects of haemodynamic forces. We developed a microfluidic device incorporating micro-contractions that harnesses well-defined haemodynamic strain gradients to initiate platelet aggregation in citrated whole blood. The microchannel architecture has been specifically designed to allow for continuous real-time imaging of platelet aggregation dynamics. Subjects aged ≥18 years with previously diagnosed VWD or who presented for evaluation of a bleeding disorder, where the possible diagnosis included VWD, were tested. Samples were obtained for device characterization as well as for pathology-based testing. Platelet aggregation in the microfluidic device is independent of platelet amplification loops but dependent on low-level platelet activation, GPIb/IX/V and integrin αβ engagement. Microfluidic output directly correlates with VWF antigen levels and is able to sensitively detect aggregation defects associated with VWD subtypes. Testing demonstrated a strong correlation with standard clinical laboratory-based tests. Head-to-head comparison with PFA100® demonstrated equivalent, if not improved, sensitivity for screening aggregation defects associated with VWD. This strain rate gradient microfluidic prototype has the potential to be a clinically useful, rapid and high throughput-screening tool for VWD as well as other strain-dependent platelet disorders. In addition, the microfluidic device represents a novel approach to examine the effects of high magnitude/short duration (ms) strain rate gradients on platelet function.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c7lc00498b | DOI Listing |
Sci Rep
January 2025
Department of Biomedical Engineering, University of Rochester, Rochester, NY, USA.
The aberrant vascular response associated with tendon injury results in circulating immune cell infiltration and a chronic inflammatory feedback loop leading to poor healing outcomes. Studying this dysregulated tendon repair response in human pathophysiology has been historically challenging due to the reliance on animal models. To address this, our group developed the human tendon-on-a-chip (hToC) to model cellular interactions in the injured tendon microenvironment; however, this model lacked the key element of physiological flow in the vascular compartment.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Instituto de Engenharia de Sistemas e Computadores-Microsistemas e Nanotecnologias (INESC-MN), Rua Alves Redol, 1000-029 Lisbon, Portugal.
Point-of-care (PoC) devices offer a promising solution for fast, portable, and easy-to-use diagnostics. These characteristics are particularly relevant in agrifood fields like viticulture where the early detection of plant stresses is crucial to crop yield. Microfluidics, with its low reagent volume requirements, is well-suited for such applications.
View Article and Find Full Text PDFMicromachines (Basel)
January 2025
Center of Competence at Mechatronics and Clean Technologies-MIRACle, "Acad. G. Bontchev" Str. 4, 1113 Sofia, Bulgaria.
Chronic lymphocytic leukemia (CLL), the most common type of leukemia, remains incurable with conventional therapy. Despite advances in therapies targeting Bruton's tyrosine kinase and anti-apoptotic protein BCL-2, little is known about their effect on red blood cell (RBC) aggregation in blood flow. In this study, we applied a microfluidic device and a newly developed Software Image Flow Analysis to assess the extent of RBC aggregation in CLL patients and to elucidate the hemorheological effects of the commonly applied therapeutics Obinutuzumab/Venetoclax and Ibrutinib.
View Article and Find Full Text PDFMicromachines (Basel)
January 2025
Department of Chemical and Biological Sciences, Faculty of Science, Japan Women's University, 2-8-1 Mejirodai, Bunkyo, Tokyo 112-8681, Japan.
Microfluidic-based cell-stretching devices are vital for studying the molecular pathways involved in cellular responses to mechanobiological processes. Accurate evaluation of these responses requires detailed observation of cells cultured in this cell-stretching device. This study aimed to develop a method for preparing microscope slides to enable high-magnification imaging of cells in these devices.
View Article and Find Full Text PDFMicromachines (Basel)
January 2025
School of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK.
This study evaluates the performance of continuous flow and drop-based microfluidic devices for the synthesis of silver nanoparticles (AgNPs) under identical hydrodynamic and chemical conditions. Flows at low values of Dean number (De < 1) were investigated, where the contribution of the vortices forming inside the drop to the additional mixing inside the reactor should be most noticeable. In the drop-based microfluidic device, discrete aqueous drops serving as reactors were generated by flow focusing using silicone oil as the continuous phase.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!