Objective: To determine whether robot-assisted gait training (RAGT) is more effective in improving mobility, endurance, gait performance, and balance in patients with multiple sclerosis (MS) compared with conventional walking rehabilitation treatment (CWT).
Data Sources: Sources included the Cochrane Library, PubMed, Embase, and Science Direct databases.
Review Method: All possible articles were retrieved by two independent investigators and relevant articles were gathered. Studies on adult patients (older than 19 years old) suffering from MS were included, regardless the subtype of MS diagnosis. Finally, we identified seven studies that comprised 205 patients with MS.
Results: We identified seven studies comprising 205 patients with MS in our meta-analysis. The pooled mean difference (MD) for the six-minute walk test (6MWT) was 14.25 [95% confidence interval (CI) 3.19 to 25.32, = 2.53, = 0.01, = 54%], which indicates that RAGT is superior to CWT on improving endurance. No significant improvement on using RAGT was found regarding the Berg Balance Scale (MD = -0.59, 95% CI: -2.7 to 1.52, = 0.55, = 0.58, = 51%), 10-meter walk test [standard mean difference (SMD) = 0.03, 95% CI: -0.26 to 0.31, = 0.18, = 0.86, = 48%] timed up and go (TUG) test (MD = -1.04, 95% CI: -8.68 to 6.60, = 0.27, = 0.79), or stride length (SMD = 0.36, 95% CI: -0.13 to 0.85, = 0.73, = 0.15).
Conclusion: We can conclude that RAGT can bring more benefits on improving 6MWT among MS patients, but it is not enough to make a clinically significance conclusion. Considering the limitation of our study, it takes reservations about recommending all MS patients to take RAGT as primary rehabilitation intervention. Unless patients with progressive MS can take conventional rehabilitation in early time, RAGT would be a suitable substitute.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5468403 | PMC |
http://dx.doi.org/10.3389/fneur.2017.00260 | DOI Listing |
Drug Alcohol Depend
January 2025
RAND, Boston, MA, United States. Electronic address:
Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.
Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.
Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.
Comput Med Imaging Graph
January 2025
CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:
In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Eur J Radiol
January 2025
Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:
Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.
View Article and Find Full Text PDFEur J Radiol
January 2025
Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:
Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.
Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!