A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of Surface Microhardness Following Chemical and Microwave Disinfection of Commercially Available Acrylic Resin Denture Teeth. | LitMetric

Introduction: Denture disinfection is an indispensable procedure for preventing cross contamination and the maintenance of a healthy oral mucosa in patients rehabilitated with removable dental prosthesis. Nevertheless, they are known to cause changes in the physical and mechanical properties of denture base resins and acrylic resin denture teeth following immersion of a denture in a suitable chemical disinfectant solution or by undergoing microwave irradiation. One such mechanical property indicator for artificial tooth materials is hardness.

Aim: To assess the surface hardness of acrylic resin teeth of three different commercial brands (Ivoclar, Newace, Acryrock) following chemical (2% glutaraldehyde, 1% sodium hypochlorite) and microwave disinfections.

Materials And Methods: Ten specimens of each of the three commercial brands were made for control and each simulated disinfection type and stored in distilled water at room temperature for 24 hours. After water storage, specimens were immersed in 2% glutaraldehyde and 1% sodium hypochlorite (one and three cycles) at room temperature for 10 minutes. Irradiation with microwave (one and three cycles) was done in domestic microwave for three minutes with the specimens immersed in 150 ml of distilled water. The specimens were stored in distilled water at room temperature for seven days after each disinfection cycle. Vickers hardness measurements were made using a hardness indenter under a load of 50 g force for 10 seconds. Data was subjected to repeated measure two-way ANOVA test and Tukey's test.

Results: There were statistically significant differences for the variables disinfection, tooth, and cycle (p<0.05 for teeth & disinfectant interaction, p<0.05 cycle and disinfectant interaction). The mean surface hardness following one microwave disinfection cycle was lower than control, glutaraldehyde and sodium hypochlorite. Comparison among cycles revealed that microhardness was significantly decreased for three cycles of microwave disinfection.

Conclusion: It was concluded that there was no significant difference in microhardness when the teeth were subjected to chemical disinfection but three cycles of microwave disinfection produced decrease in the microhardness of different types of artificial teeth.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5483818PMC
http://dx.doi.org/10.7860/JCDR/2017/27587.9944DOI Listing

Publication Analysis

Top Keywords

acrylic resin
12
distilled water
12
room temperature
12
resin denture
8
denture teeth
8
three commercial
8
commercial brands
8
glutaraldehyde sodium
8
sodium hypochlorite
8
stored distilled
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!