We report a case of left atrial extrinsic compression caused by an esophageal food bolus in a patient presenting with acute heart failure. Transthoracic echocardiography along with contrast-enhanced CT showed evidence of esophageal dilation producing left atrial compression. Esophageal endoscopy and fragmentation of the bolus, allowing the accumulated food to descend into the stomach, produced a rapid improvement of hemodynamic and clinical status. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 46:259-261, 2018.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/jcu.22512 | DOI Listing |
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Pak J Med Sci
January 2025
Zhuqing Ji Department of Medicine Oncology, The Affiliated Huai'an 1st People's Hospital of Nanjing Medical University, Huaian, Jiangsu Province 223300, P.R. China.
Objective: To explore the risk factors associated with postoperative atrial fibrillation (POAF) after off-pump coronary artery bypass grafting (OPCABG) and to construct a nomogram predictive model.
Methods: In this retrospective cohort study, clinical data of 193 patients who received OPCABG in Huai'an First People's Hospital Affiliated to Nanjing Medical University from June 2021 to November 2023 were retrospectively analyzed. Based on the established diagnosis of POAF, patients were divided into the POAF group (n=75) and the non-POAF group (n=118).
JACC Adv
February 2025
Department of Cardiovascular Medicine, Mayo Clinic College of Medicine and Science, Rochester, Minnesota, USA.
Background: Up to 50% of patients undergoing mitral transcatheter edge-to-edge repair (MTEER) have an indication for left atrial appendage occlusion (LAAO). However, prospective evaluation of this strategy is lacking.
Objectives: The aim of the study was to prospectively evaluate the outcomes of combined LAAO and MTEER.
Rev Cardiovasc Med
January 2025
Department of Echocardiography and Cardiology, The First People's Hospital of Changzhou, 213003 Changzhou, Jiangsu, China.
Background: This article focuses on the effect of body mass index (BMI) on cardiac structure and function in cases with non-valvular atrial fibrillation (NVAF). Only a few articles have investigated the relationship between BMI and the incidence of left atrial thrombus (LAT) or spontaneous echo contrast (SEC) in cases with NVAF.
Methods: This single-center retrospective study was conducted at The First People's Hospital of Changzhou.
Rev Cardiovasc Med
January 2025
Department of Cardiology, Renmin Hospital of Wuhan University, 430060 Wuhan, Hubei, China.
With a better understanding of the susceptibility to atrial fibrillation (AF) and the thrombogenicity of the left atrium, the concept of atrial cardiomyopathy (ACM) has emerged. The conventional viewpoint holds that AF-associated hemodynamic disturbances and thrombus formation in the left atrial appendage are the primary causes of cardiogenic embolism events. However, substantial evidence suggests that the relationship between cardiogenic embolism and AF is not so absolute, and that ACM may be an important, underestimated contributor to cardiogenic embolism events.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!