The method of angular- and wavelength-dispersive ( two-dimensional) Rietveld refinement is a new and emerging tool for the analysis of neutron diffraction data measured at time-of-flight instruments with large area detectors. Following the approach for one-dimensional refinements (using either scattering angle or time of flight), the first step at each beam time cycle is the calibration of the instrument including the determination of instrumental contributions to the peak shape variation to be expected for diffraction patterns measured by the users. The aim of this work is to provide the users with calibration files and - for the later Rietveld refinement of the measured data - with an instrumental resolution file (IRF). This article will elaborate on the necessary steps to generate such an IRF for the angular- and wavelength-dispersive case, exemplified for the POWGEN instrument. A dataset measured on a standard diamond sample is used to extract the profile function in the two-dimensional case. It is found that the variation of reflection width with 2θ and λ can be expressed by the standard equation used for evaluating the instrumental resolution, which yields a substantially more fundamental approach to the parameterization of the instrumental contribution to the peak shape. Geometrical considerations of the POWGEN instrument and sample effects lead to values for Δθ, Δ and Δ that yield a very good match to the extracted FWHM values. In a final step the refinement results are compared with the one-dimensional, diffraction-focused, case.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5458595PMC
http://dx.doi.org/10.1107/S1600576717005398DOI Listing

Publication Analysis

Top Keywords

instrumental resolution
12
powgen instrument
12
scattering angle
8
exemplified powgen
8
angular- wavelength-dispersive
8
rietveld refinement
8
peak shape
8
instrumental
5
resolution function
4
function scattering
4

Similar Publications

MALDI-MSI: A potential game changer in forensic sciences.

Forensic Sci Med Pathol

January 2025

School of Biochemistry and Biotechnology, University of the Punjab, Lahore, Pakistan.

Matrix-assisted laser Desorption/Ionization Mass Spectrometry Imaging (MALDI MSI) is an analytical technique used for the spatial mapping of drugs, explosives, and organic samples, making it a game-changer in Forensic examination. It detects a wide range of biomolecules in their native state without specific tags, antibodies, labels, and dyes. This review aims to highlight the advancement of MALDI-MSI over time and its impact on Forensic Science due to high-resolution molecular imaging.

View Article and Find Full Text PDF

Delayed subaponeurotic fluid collection (DSFC) is an uncommon condition that causes scalp swelling in infants, usually appearing within the first weeks to months of life. Although the precise etiology is unclear, DSFC is frequently associated with instrumental or traumatic deliveries. We report two cases of DSFC: a 12-week-old boy and a six-week-old girl, both presenting with progressive, fluctuant scalp swelling without any history of trauma.

View Article and Find Full Text PDF

Exploring the Vibrational Coherences in the Ultrafast Electronic Relaxation of Pyrimidine Nucleobases and Nucleosides.

J Am Chem Soc

January 2025

Department of Chemistry, Graduate School of Science, Kyoto University, Kitashirakawa-Oiwakecho, Sakyo-Ku, Kyoto 606-8502, Japan.

We studied the vibrational coherences during the ultrafast internal conversions (ICs) of pyrimidine nucleobases and -sides in aqueous solutions and the gas phase with an instrumental resolution of 14 fs. The coherence of the same ring-breathing vibrational mode with a frequency of 750 cm was observed. In the gas phase, the vibrational coherence was transferred during IC from the ππ* to the nπ* state, and it survived for approximately 1 ps.

View Article and Find Full Text PDF

Controlling the light emitted by individual molecules is instrumental to a number of advanced nanotechnologies ranging from super-resolution bioimaging and molecular sensing to quantum nanophotonics. Molecular emission can be tailored by modifying the local photonic environment, for example, by precisely placing a single molecule inside a plasmonic nanocavity with the help of DNA origami. Here, using this scalable approach, we show that commercial fluorophores may experience giant Purcell factors and Lamb shifts, reaching values on par with those recently reported in scanning tip experiments.

View Article and Find Full Text PDF

Clinical and Electromyographic Characteristics of Pediatric Laryngeal Dyskinesia.

Otolaryngol Head Neck Surg

January 2025

Divisions of Pediatric Surgery and Otolaryngology-Head and Neck Surgery, The Stollery Children's Hospital and University of Alberta Hospital, Edmonton, Alberta, Canada.

Objective: To report the clinical and laryngeal electromyographic (LEMG) parameters of children with laryngeal dyskinesia (LD) and its prevalence among laryngeal mobility disorder (LMD) requiring full airway examination.

Study Design: Retrospective uncontrolled study.

Setting: Tertiary pediatric center.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!