A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of nitrous oxide on bispectral index values at equi-minimum alveolar concentrations of sevoflurane and desflurane. | LitMetric

Background And Aims: Bispectral index (BIS) values may be anaesthetic agent-specific, depending on their ability to suppress the electroencephalogram (EEG) signals. We carried out a prospective, randomised clinical trial to study the effect of nitrous oxide (NO) on the BIS values at an equi-minimum alveolar concentration (MAC) of sevoflurane and desflurane.

Methods: Sixty adult patients undergoing spine surgery were randomised into two groups; Group S (sevoflurane; = 30) and Group D (desflurane; = 30) for the maintenance of anaesthesia in oxygen and air or oxygen and NO mixture (FiO-0.4) (Stage 1). BIS and fraction of inspired and end-tidal concentration of agents were noted at 1.0 MAC. In Stage 2, air or NO was discontinued and the other carrier gas was introduced. At steady state of this carrier gas, values were again noted as in Stage 1. Statistical analysis was performed using two-way analysis of variance followed by Bonferroni correction, and Student's -test for paired data. <0.05 was considered statistically significant.

Results: With air-oxygen as the carrier gas, sevoflurane and desflurane resulted in comparable BIS values ( = 0.44). With addition of 60% NO, there was a significant increase in BIS values at 1.0 MAC for both the agents. Furthermore, higher BIS values were observed with sevoflurane compared to desflurane ( = 0.01).

Conclusion: Sevoflurane and desflurane at equi-MAC concentration exert similar effect on BIS values when used with air-oxygen. NO results in higher BIS values; this effect is more pronounced in combination with sevoflurane.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5474916PMC
http://dx.doi.org/10.4103/ija.IJA_363_16DOI Listing

Publication Analysis

Top Keywords

nitrous oxide
8
values equi-minimum
8
equi-minimum alveolar
8
bis values
8
carrier gas
8
oxide bispectral
4
values
4
bispectral values
4
alveolar concentrations
4
concentrations sevoflurane
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!