Purpose: To evaluate the Patient-Reported Outcomes Measurement Information System upper extremity item bank (PROMIS UE) and physical function computerized adaptive test (PROMIS PF CAT) in patients with rotator cuff (RC) pathology at their preoperative clinic visit.

Methods: Patient data were collected from January 2015 to September 2015. Patients with a preoperative diagnosis of RC pathology were prospectively enrolled at the time of their surgical indication for RC repair. Each patient was asked to fill out the Western Ontario Rotator Cuff Index (WORC), American Shoulder and Elbow Surgeons Shoulder Assessment Form, Marx Shoulder Activity Scale, Short Form 36 Health Survey Physical Function and General Health (SF-36 PF and GH), EuroQol-5 Dimension (EQ-5D), PROMIS PF CAT, and PROMIS UE. Correlation was defined as excellent (>0.7), excellent-good (0.61-0.7), good (0.4-0.6), and poor (0.2-0.3).

Results: Patient data were collected from January 2015 to September 2015. No patients were excluded from participation in the study. In 82 patients with preoperative RC pathology, the PROMIS UE showed excellent correlation with American Shoulder and Elbow Surgeons Shoulder Assessment Form (r = 0.77, P < .01), WORC (r = 0.73, P < .01), and the EQ-5D (r = 0.73, P < .01); there was excellent-good correlation with the SF-36 PF (r = .66, P < .01) and PROMIS PF CAT (r = .70, P < .01). The PROMIS PF CAT showed excellent correlation with the SF-36 PF (r = 0.77, P < .01); there was excellent-good correlation with EQ-5D (r = 0.65, P < .01) and WORC (r = 0.61, P < .01). There were no significant floor or ceiling effects using the PROMIS UE item bank or PROMIS PF CAT.

Conclusions: We report that in a patient population with preoperative RC pathology, the PROMIS UE and PROMIS CAT are valid patient-reported outcome alternatives that have high correlation with traditional shoulder and upper extremity patient-reported outcomes. We find a decreased question burden using the PROMIS PF CAT. We find no significant floor or ceiling effects present in the PROMIS UE or PROMIS PF CAT.

Level Of Evidence: Level II, prospective diagnostic study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2017.04.018DOI Listing

Publication Analysis

Top Keywords

promis cat
24
promis
14
patient-reported outcomes
12
rotator cuff
12
outcomes measurement
8
measurement system
8
patients rotator
8
cuff pathology
8
upper extremity
8
item bank
8

Similar Publications

Purpose: The objective of this study is to assess the psychometric properties and reliability of the Swedish Patient-Reported Outcomes Measurement Information System (PROMIS) item banks for anxiety and depressive symptoms with item response theory analysis and post-hoc computerized adaptive testing in a combined Swedish Child and Adolescent Psychiatry (CAP) and school sample.

Methods: Participants (n = 928, age 12-20) were recruited from junior and high schools and Child and Adolescent Psychiatry Clinics in the region of Västerbotten. Unidimensionality, local independence, and monotonicity was tested.

View Article and Find Full Text PDF

Background: There is no standardization within hand and upper-extremity surgery regarding which patient-reported outcome measures (PROMs) are collected and reported. This limits the ability to compare or combine cohorts that utilize different PROMs. The aim of this study was to develop a linkage model for the QuickDASH (shortened version of the Disabilities of the Arm, Shoulder and Hand) and PROMIS PF CAT (Patient-Reported Outcomes Measurement Information System Physical Function computerized adaptive testing) instruments to allow interconversion between these PROMs in a hand surgery population.

View Article and Find Full Text PDF

Background: To assess fatigue in cancer patients, several patient-reported outcome measures (PROMs) are available that differ in content. To support the selection of suitable measures for specific applications and to evaluate possibilities of quantitative linking, the present study provides a content comparison of common fatigue measures, scales, and item banks. We included the EORTC CAT Core, EORTC QLQ-FA12, EORTC QLQ-C30, FACIT-F, PROMIS Fatigue (Cancer item bank v1.

View Article and Find Full Text PDF

Background: The commonly used ('legacy') PROMs evaluating outcomes of total hip arthroplasty (THA), have several limitations regarding their measurement properties and interpretation of scores. One innovation in PROMs is the use of Computerized Adaptive Testing (CAT). The Patient-Reported Outcomes Measurement Information System (PROMIS) is a validated system of CATs.

View Article and Find Full Text PDF

Background: The Optimal Screening for Prediction of Referral and Outcome Yellow Flag (OSPRO-YF) Tool is a 10-item multidimensional screening tool utilized to evaluate pain-related psychological traits in individuals with musculoskeletal pain conditions. The validity of postoperatively collected OSPRO-YF is unclear. This study sought to assess validity of the OSPRO-YF by comparing it to patient-reported outcome scores in both preoperative and postoperative settings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?