A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of a telemetric gastrointestinal pill for continuous monitoring of gastrointestinal temperature in horses at rest and during exercise. | LitMetric

AI Article Synopsis

  • The study aimed to assess the effectiveness of a telemetric gastrointestinal (GI) pill for monitoring GI temperature in horses, comparing it to traditional rectal temperature measurements.
  • Eight Standardbred horses were used, and tests showed the GI pill slightly underestimated temperature, but it still provided reliable continuous data during rest and exercise over three days.
  • Overall, the GI pill proved to be a practical method for real-time temperature monitoring in horses, with a consistent temperature difference noted compared to rectal measurements.

Article Abstract

OBJECTIVE To evaluate use of a telemetric gastrointestinal (GI) pill to continuously monitor GI temperature in horses at rest and during exercise and to compare time profiles of GI temperature and rectal temperature. ANIMALS 8 Standardbred horses. PROCEDURES Accuracy and precision of the GI pill and a rectal probe were determined in vitro by comparing temperature measurements with values obtained by a certified resistance temperature detector (RTD) in water baths at various temperatures (37°, 39°, and 41°C). Subsequently, both GI and rectal temperature were recorded in vivo in 8 horses over 3 consecutive days. The GI temperature was recorded continuously, and rectal temperature was recorded for 3.5 hours daily. Comparisons were made between GI temperature and rectal temperature for horses at rest, during exercise, and after exercise. RESULTS Water bath evaluation revealed good agreement between the rectal probe and RTD. However, the GI pill systematically underestimated temperature by 0.14°C. In vivo, GI temperature data were captured with minimal difficulties. Most data loss occurred during the first 16 hours, after which the mean ± SD data loss was 8.6 ± 3.7%. The GI temperature was consistently and significantly higher than rectal temperature with an overall mean temperature difference across time of 0.27°C (range, 0.22° to 0.32°C). Mean measurement cessation point for the GI pill was 5.1 ± 1.0 days after administration. CONCLUSIONS AND CLINICAL RELEVANCE This study revealed that the telemetric GI pill was a reliable and practical method for real-time monitoring of GI temperature in horses.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.78.7.778DOI Listing

Publication Analysis

Top Keywords

rectal temperature
20
temperature
17
temperature horses
16
horses rest
12
rest exercise
12
temperature recorded
12
telemetric gastrointestinal
8
gastrointestinal pill
8
temperature rectal
8
rectal probe
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!