Objective: Digital subtraction angiography (DSA) of the peripheral arterial vasculature provides lumenographic information but only a qualitative assessment of blood flow. The ability to quantify adequate tissue perfusion of the lower extremities would enable real-time perfusion assessment during DSA of patients with peripheral arterial disease (PAD). In this study, we used a novel real-time imaging software to delineate tissue perfusion parameters in the foot in PAD patients.

Methods: Between March 2015 and June 2016, patients (N = 31) underwent lower extremity angiography using a two-dimensional perfusion (2DP) imaging protocol (Philips Healthcare, Andover, Mass). Of the 31 enrolled patients, 16 patients received preintervention and postintervention DSA images (18 angiograms), while contrast agent injection settings and the position of the foot, catheter, and C-arm were kept constant. The region of interest for perfusion measurements was taken at the level of the medial malleolus. Perfusion parameters included arrival time (AT) of contrast material, wash-in rate (WIR), time to peak (TTP) contrast intensity, and area under the curve (AUC).

Results: Patients (mean age, 67 years; male, 61%) undergoing 2DP had limbs classified as Rutherford class 3 (n = 9 limbs), class 4 (n = 11), and class 5 (n = 14) ischemia with a mean ankle-brachial index of 0.63. For the whole cohort, median (interquartile range) AT measured 5.20 (3.10-7.25) seconds; WIR, 61.95 (43.53-86.43) signal intensity (SI)/s; TTP, 3.80 (2.88-4.50) seconds; peak intensity, 725.00 (613.75-1138.00) SI; and AUC, 12,084.00 (6742.80-17,059.70) SI*s. A subset of patients had 2DP performed before and after intervention (n = 18 cases). A detectable improvement in SI and two-dimensional flow parameters was seen after intervention. Average AT of contrast material to the region of interest shortened after intervention with percentage decrease of 30.1% ± 49.1%, corresponding decrease in TTP of 17.6% ± 24.7%, increase in WIR of 68.8% ± 94.2% and in AUC of 10.5% ± 37.6%, decrease in mean transit time of 18.7% ± 28.1%, and increase in peak of 34.4% ± 42.2%.

Conclusions: The 2DP imaging allows measurement of blood flow in real time as an adjunct to DSA. The AT may be the most sensitive marker of perfusion change in the lower extremity. Quantitative thresholds based on 2DP hold promise for immediate treatment effectiveness assessment in patients with PAD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2017.03.424DOI Listing

Publication Analysis

Top Keywords

tissue perfusion
12
lower extremity
12
class n =
12
perfusion
8
perfusion lower
8
digital subtraction
8
subtraction angiography
8
peripheral arterial
8
blood flow
8
perfusion parameters
8

Similar Publications

Quantitative pre-clinical imaging of hypoxia and vascularity using MRI and PET.

Methods Cell Biol

January 2025

Translational Radiomics, Luxembourg Institute of Health, Luxembourg City, Luxembourg; In-Vivo Imaging Platform, Luxembourg Institute of Health, Luxembourg City, Luxembourg.

During hypoxia, tissues are subjected to an inadequate oxygen supply, disrupting the balance needed to maintain normal function. This deficiency can occur due to reduced oxygen delivery caused by impaired blood flow or a decline in the blood's ability to carry oxygen. In tumors, hypoxia and vascularization play crucial roles, shaping their microenvironments and influencing cancer progression, response to treatment and metastatic potential.

View Article and Find Full Text PDF

Permeability is a measure of the degree to which cells can transport molecules across biological barriers. Units of permeability are distance per unit time (typically cm/s), where accurate measurements are needed to define drug delivery in homeostasis and to model dysfunction occurring during disease. This perspective offers a set of community-led guidelines to benchmark permeability data across multidisciplinary approaches and different biological contexts.

View Article and Find Full Text PDF

Background: Infertility is a special reproductive health defect. For women, congenital uterine malformations, extensive adhesions in the uterine cavity, and hysterectomy are associated with infertility. Uterine transplantation is technically feasible, but its clinical application and development are limited by donor shortages and immune rejection.

View Article and Find Full Text PDF

Human brain organoids (HBOs) derived from pluripotent stem cells hold great potential for disease modeling and high-throughput compound screening, given their structural and functional resemblance to fetal brain tissues. These organoids can mimic early stages of brain development, offering a valuable in vitro model to study both normal and disordered neurodevelopment. However, current methods of generating HBOs are often low throughput and variable in organoid differentiation and involve lengthy, labor-intensive processes, limiting their broader application in both academic and industrial research.

View Article and Find Full Text PDF

Human liver organoids (HLOs) derived from pluripotent stem cells hold potential for disease modeling and high-throughput compound screening due to their architectural and functional resemblance to human liver tissues. However, reproducible, scale-up production of HLOs for high-throughput screening (HTS) presents challenges. These include the high costs of additives and growth factors required for cell differentiation, variability in organoid size and function from batch to batch, suboptimal maturity of HLOs compared to primary hepatocytes, and low assay throughput due to excessive manual processes and the absence of assay-ready plates with HLOs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!