A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ridge preservation using an in situ hardening biphasic calcium phosphate (β-TCP/HA) bone graft substitute-a clinical, radiological, and histological study. | LitMetric

Background: Post-Extraction ridge preservation using bone graft substitutes is a conservative technique to maintain the width of the alveolar ridge. The objective of the present study was to evaluate an in situ hardening biphasic (HA/β-TCP) bone graft substitutes for ridge preservation without primary wound closure or a dental membrane.

Methods: A total of 15 patients reported for tooth extraction were enrolled in this study. Implants were placed in average 5.2 ± 2 months after socket grafting. At this visit, Cone Beam CT (CBCT) images and core biopsies were taken. Implant stability (ISQ) was assessed at the insertion as well as at the day of final restoration.

Results: CBCT data revealed 0.79 ± 0.73 mm ridge width reduction from grafting to implant placement. Histomorphometric analysis of core biopsy samples revealed in average 21.34 ± 9.14% of new bone in the grafted sites. Primary implant stability was high (ISQ levels 70.3 ± 9.6) and further increased until final restoration.

Conclusions: The results of this study show that grafting of intact post-extraction sockets using a biphasic in situ hardening bone graft substitute results in an effective preservation of the ridge contour and sufficient new bone formation in the grafted sites, which is imperative for successful implant placement.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5481287PMC
http://dx.doi.org/10.1186/s40729-017-0086-2DOI Listing

Publication Analysis

Top Keywords

bone graft
16
ridge preservation
12
situ hardening
12
hardening biphasic
8
graft substitutes
8
implant stability
8
implant placement
8
grafted sites
8
ridge
6
bone
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!