Bonding of zirconia crowns and bridges to abutments is important, not only bonding of the thin resin layer to the abutment, but also bonding to the zirconia ceramic is crucial. Both mechanical and chemical adhesion are desired. Mechanical retention of dental porcelain achieved by etching with moderately concentrated hydrofluoric acid is not possible with zirconia ceramics. The purpose of this study was to show that etching is possible with relative low melting fluoride compounds such as ammonium hydrogen difluoride and potassium hydrogen difluoride. Before melting, the fluorides can be introduced as powders or as aqueous slurries to the contact surfaces of the zirconia. After melting, the yttria-stabilized zirconia surface revealed a surface similar to an HF-etched dental feldspathic porcelain surface. Shear bond testing ( = 10) was performed with zirconia attached to zirconia with the Duo-Link composite luting cement (Bisco) after treatment of the etched zirconia surfaces with Bis-Silane (Bisco) and the Porcelain Bonding Resin (Bisco). Values for adhesive strength (mean ± standard deviation) after melt etching of the surfaces with initially dry powders were for K[FHF], (31.2 ± 7.5) MPa and for NH[FHF] (31.0 ± 11.8) MPa. When initially aqueous slurries were applied, the values were for K[FHF] (42.7 ± 12.7) MPa and for NH[FHF] (40.3 ± 10.0) MPa. Good adhesion to zirconia can be achieved by a procedure including etching with selected melted fluoride compounds.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5463337PMC
http://dx.doi.org/10.1080/23337931.2017.1309658DOI Listing

Publication Analysis

Top Keywords

zirconia
10
zirconia ceramics
8
bonding zirconia
8
fluoride compounds
8
hydrogen difluoride
8
aqueous slurries
8
mpa nh[fhf]
8
novel etching
4
etching technique
4
surface
4

Similar Publications

Objectives: This study aims to compare the clinical performance of 3D printed endocrowns (ECs) and prefabricated zirconia crowns (PZRCs) in restoring pulpotomized primary molars, over 3, 6, and 12 months.

Methods: Thirty pulpotomized mandibular primary molars in 16 children aged 4-8 years were randomized with a 1:1 allocation ratio into two groups: group (A), PZRCs, and group (B), 3D-printed ECs. All restorations were evaluated for esthetic, functional, and biological properties using FDI criteria at 3-, 6-, and 12-month intervals.

View Article and Find Full Text PDF

Load-bearing capacity of screw-retained fixed dental prostheses made of monolithic zirconia on different abutment designs and abutment-free implant connection.

J Dent

January 2025

Senior Research and Teaching Assistant, Clinic of Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, 8032 Zurich, Switzerland. Electronic address:

Objectives: A new abutment-free implant connection allows for direct screwing of FDPs on implants to avoid complications caused by cement rests or screw loosening, which may affect to screw torque and load distribution. The objective of this study was to test the initial (Fi) and final failure (Ff) loads and torque changes of abutment-free monolithic zirconia CAD-CAM fixed dental prostheses (FDPs) compared to titanium FDPs on different abutment designs.

Methods: Three-unit screw-retained FDPs (n=50) on two implants (n=100) were divided into groups (n=10) based on the implant-abutment connection and material of the supra-structure: (1) abutment-free monolithic CAD-CAM zirconia FDP (Abut-free-Zr), (2) abutment-free veneered titanium FDPs (Abut-free-Ti), (3) monolithic zirconia FDPs with titanium base abutments (Zr-Ti-Base), (4) monolithic zirconia FDPs on multi-unit abutments (Zr-MU), (5) veneered titanium FDP on multi-unit abutments (Ti-MU).

View Article and Find Full Text PDF

Purpose: To assess the impact of staining and multiple firings on the mechanical, optical, and surface characteristics of zirconia-containing lithium silicate ceramics (ZLS).

Materials And Methods: Ninety ZLS discs (Suprinity, VITA Zahnfabrick) were divided according to the "Number of firings" protocol: Ctr-control, no characterization; SC-single firing cycle (for characterization, crystallization and staining simultaneously); and DC-double firing cycle (crystallization firing cycle was performed separately from the staining firing). Extrinsic pigmentation was performed to replicate the characterization of a monolithic restoration.

View Article and Find Full Text PDF

Influence of gingival color and abutment material on the final color of peri-implant soft tissue: An in vitro analysis.

J Oral Implantol

January 2025

Professor, Department of Prosthodontics, Faculty of Dentistry, University of Atlas, Istanbul, Turkey.

The study aimed to investigate the influence of different gingival colors and abutment materials on the final color of peri-implant soft tissue. A total of 30-cylinder shaped specimens having 1.0- and 2.

View Article and Find Full Text PDF

Full-arch implant-supported rehabilitation using reverse scan technique: A case report.

J Oral Implantol

January 2025

Department of Orthodontics and Pedodontics, Faculty of Dentistry, Van Lang University, Ho Chi Minh City, Vietnam.

The reverse scan technique offers several advantages, such as improvements of accuracy and visibility of critical anatomical structures, minimizing chair time, and providing better patient comfort. This was a case report successfully employing the reverse scan technique. A 72-year-old male patient desired to restore his teeth in both jaws, as he experienced difficulty eating and had never worn dentures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!