Objectives: This study aimed to investigate the diagnostic sensitivity of the cutoff values of IgG4-positive plasma cell (PC) number and IgG4-positive/CD138-positive cell ratio proposed by the International consensus statement (ICS) on the pathology of IgG4-related disease (IgG4-RD) in typical multiple lesions of patients with IgG4-RD.

Methods: We evaluated IgG4-positive PC number and IgG4-positive/CD138-positive cell ratio in 39 samples from 18 IgG4-RD patients having more than two typical lesions of IgG4-RD.

Results: We evaluated 12 submandibular, 12 ophthalmic, six skin, five kidney, two pancreatic, and one bronchus and prostate lesion each in 18 patients with typical clinical, serological, and radiographic features. Concerning IgG4 + PC number per high-power field, most ophthalmic (11/12), kidney (5/5), pancreatic (2/2), and bronchial lesions (1/1) fulfilled the cutoff value of ICS, whereas many of the submandibular (6/12) and skin lesions (0/6) did not. In contrast to the absolute number, all lesions fulfilled the cutoff value of IgG4+/CD138 + cell ratio. In eight cases, only one or two lesions in the same patient fulfilled the cutoff value of ICS, while the others did not.

Conclusions: These results suggest that ICS criteria have different sensitivities among the affected organs for the diagnosis of IgG4-RD.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14397595.2017.1332540DOI Listing

Publication Analysis

Top Keywords

number igg4-positive/cd138-positive
12
igg4-positive/cd138-positive cell
12
cell ratio
12
fulfilled cutoff
12
diagnostic sensitivity
8
sensitivity cutoff
8
cutoff values
8
values igg4-positive
8
igg4-positive plasma
8
plasma cell
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!