Background: The aim of this study was to investigate the relationship between vertical jumping performance, isokinetic strength of knee extensors/flexors, and postural priority and to describe a multiple regression model that accounts for the effects of selected parameters of isokinetic strength and postural priority on vertical jumping performance.
Methods: Thirty-one professional male soccer players, aged from 17 to 20 years, participated in this study (age, mean±SD: 18.6±1.26 years; height: 1.78±0.74 m and weight: 73.1±6.77 kg). The correlations between isokinetic knee strength, jumping performance, and postural control were evaluated using the Pearson correlation coefficient. A linear regression model was used to evaluate the effect of hamstrings and quadriceps peak torque of both legs at 60º·s-1, total work of both legs at 240º·s-1, and postural priority on jumping performance.
Results: The peak torque of right leg knee flexor (quadriceps) muscles, evaluated at 60º·s-1 speed, showed correlations with counter movement jump, 30 second jumping and squat jump (P=0.005, P=0.003, and P=0.007, respectively). We also observed a strong relationship between counter movement jump and 30 second jumping and peak torque of left leg evaluated at the same speed of 60º·s-1 (P=0.26 and P=0.22, respectively). No significant correlations were found between any of the jumping tests and peak torque of knee extensors of both legs at 60º·s-1. For the 30 second jumping test, it appears that jumping endurance has a significant relationship with total work of knee flexors for right and left legs at 240º·s-1.
Conclusions: The results of this study demonstrate practical implications for soccer performance, but further exploration is required.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.23736/S0022-4707.17.07289-9 | DOI Listing |
Acta Bioeng Biomech
September 2024
Faculty of Computer Science, Kazimierz Wielki University, Bydgoszcz, Poland.
Monitoring and assessing the level of lower limb motor skills using the Biodex System plays an important role in the training of football players and in post-traumatic rehabilitation. The aim of this study was to build and test an artificial intelligence-based model to assess the peak torque of the lower limb extensors and flexors. The model was based on real-world results in three groups: hearing ( = 19) and deaf football players ( = 28) and non-training deaf pupils ( = 46).
View Article and Find Full Text PDFActa Bioeng Biomech
September 2024
Department of Biomedical Basis of Physical Culture, Faculty of Health Science and Physical Culture, Kazimierz Wielki University in Bydgoszcz, Poland.
Soccer is a sport being performed in a very dynamic manner. It requires soccer players to be able to develop high muscle force in a very short period of time. The aim of the study was to evaluate the strength and jumping abilities of young soccer players playing in different positions on the field.
View Article and Find Full Text PDFEur J Sport Sci
February 2025
Department of Sport and Health Sciences and Social Work, Oxford Brookes University, Oxford, UK.
Some technical limitations to using the eccentric mode to measure peak eccentric strength of the hamstrings (PTH) were raised. PTH also has limited validity to predict performance or injury risk factor. Therefore, our aim was to compare PTH and other isokinetic variables tested in the eccentric and passive modes.
View Article and Find Full Text PDFFree Radic Biol Med
January 2025
University of Exeter, Medical School, Faculty of Health and Life Sciences, St Luke's Campus, Exeter, EX1 2LU, UK. Electronic address:
Plasma nitrate (NO) and nitrite (NO) increase in a dose-dependent manner following NO ingestion. To explore if the same dose-response relationship applies to other nitric oxide (NO) congeners in different blood compartments and skeletal muscle, as well as the subsequent physiological responses, we provided 11 healthy participants with NO depleted beetroot juice (placebo), and beetroot juice (BR) containing 6.4, 12.
View Article and Find Full Text PDFJ Foot Ankle Surg
January 2025
Enovis Foot & Ankle, Atlanta, GA; Georgia Institute of Technology, Atlanta, GA. Electronic address:
Orthopedic screws are widely used to achieve bone reduction, compression, and construct stability. However, the relationship between insertion torque, interfragmentary compression, and fixation strength, especially when comparing standard screws with NiTiNOL/sustained dynamic compression (SDC), has not been thoroughly investigated. This study measured insertion torque, interfragmentary compression, and fixation strength for two types of headed orthopedic devices-standard and SDC-using solid foam bone replicates and cadaver validation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!