Near-Real Time Measurement of Carbonaceous Aerosol Using Microplasma Spectroscopy: Application to Measurement of Carbon Nanomaterials.

Aerosol Sci Technol

Environmental Engineering and Science Program, Department of Biomedical, Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, OH, 45221.

Published: August 2016

AI Article Synopsis

  • A new microplasma spectroscopy method has been created for real-time analysis of carbon nanomaterials using laser-induced breakdown and spark emission spectroscopy.
  • The system effectively measures total atomic carbon by concentrating aerosol on a microelectrode and features a low detection limit of 1.61 ng.
  • Improvements in selectivity for elemental carbon were achieved by heating the cathode, making this method a promising option for portable and affordable monitoring of carbon aerosols.

Article Abstract

A sensitive, field-portable microplasma spectroscopy method has been developed for real-time measurement of carbon nanomaterials. The method involves microconcentration of aerosol on a microelectrode tip for subsequent analysis for atomic carbon using laser-induced breakdown spectroscopy (LIBS) or spark emission spectroscopy (SES). The spark-induced microplasma was characterized by measuring the excitation temperature (15,000 - 35,000 K), electron density (1.0 × 10 - 2.2 × 10 cm), and spectral responses as functions of time and interelectrode distance. The system was calibrated and detection limits were determined for total atomic carbon (TAC) using a carbon emission line at 247.856 nm (C I) for various carbonaceous materials including sucrose, EDTA, caffeine, sodium carbonate, carbon black, and carbon nanotubes. The limit of detection for total atomic carbon was 1.61 ng, equivalent to 238 ng m when sampling at 1.5 L min for 5 min. To improve the selectivity for carbon nanomaterials, which consist of elemental carbon (EC), the cathode was heated to 300 °C to reduce the contribution of organic carbon to the total atomic carbon. Measurements of carbon nanotube aerosol at elevated electrode temperature showed improved selectivity to elemental carbon and compared well with the measurements from thermal optical method (NIOSH Method 5040). The study shows that the SES method to be an excellent candidate for development as a low-cost, hand-portable, real-time instrument for measurement of carbonaceous aerosols and nanomaterials.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476210PMC
http://dx.doi.org/10.1080/02786826.2016.1224804DOI Listing

Publication Analysis

Top Keywords

atomic carbon
16
carbon
14
carbon nanomaterials
12
total atomic
12
measurement carbonaceous
8
microplasma spectroscopy
8
measurement carbon
8
elemental carbon
8
method
5
near-real time
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!