A small animal micro-CT system was built using an EMCCD detectors having complex pre-digitization amplification technology, high-resolution, high-sensitivity and low-noise. Noise in CBCT reconstructed images when using pre-digitization amplification behaves differently than commonly used detectors and warrants a detailed investigation. In this study, noise power and contrast sensitivity were estimated for the newly built system. Noise analysis was performed by scanning a water phantom. Tube voltage was lowered to minimum delivered by the tube (20 kVp and 0.5 mA) and detector gain was varied. Contrast sensitivity was analyzed by using a phantom containing different iodine contrast solutions (20% to 70%) filled in six different tubes. First, we scanned the phantom using various x-ray exposures at 40 kVp while changing the gain to maintain the background air value of the projection images constant. Next, the exposure was varied while the detector gain was maintained constant. Radial NPS plots show that noise power level increases as gain increases. Contrast sensitivity was analyzed by calculating ratio of signal-to-noise ratios (SNR) for increased gain with those of low constant gain at each exposure. The SNR value at low constant gain was always lower than SNR of high detector gain at all x-ray settings and iodine contrast. The largest increase of SNR approached 1.3 for low contrast feature for an iodine concentration of 20%. Despite an increase in noise level as gain increases, the SNR improvement shows that signal level also increases because of the unique on-chip gain of the detector.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5476204 | PMC |
http://dx.doi.org/10.1117/12.2216794 | DOI Listing |
Front Immunol
January 2025
Department of Hematology and Cancer Institute (Key Laboratory of Cancer Prevention and Intervention, China National Ministry of Education), The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
Immune dysfunction is one of the hallmarks of cancer and plays critical roles in immunotherapy resistance, but there is no serum biomarker that can be used to evaluate immune-dysfunction status of cancer patients. Here, we identified subtype-specific human endogenous retrovirus K102 envelope (HERV-K102-Env) with immunosuppressive activity in circulating blood as a novel serum immunosuppressive biomarker of cancer. We first generated monoclonal antibodies against K102-Env with high sensitivity and specificity, and we developed an ELISA assay to detect serum K102-Env.
View Article and Find Full Text PDFFront Neurosci
January 2025
School of Optometry, The Hong Kong Polytechnic University, Hung Hom, Hong Kong SAR, China.
Purpose: Astigmatism can lead to meridional amblyopia, an orientation-specific visual deficit. This study investigated the effects of astigmatism on meridional anisotropy in contrast sensitivity (CS) and steady-state visual evoked potential (ssVEP) across a range of spatial frequencies.
Methods: Thirty-two young adults with a best-corrected distance visual acuity of logMAR 0 or better were categorized into two groups: highly astigmatic (HAS, = 16) with spherical-equivalent error (SE) ≥ -6.
Brain Spine
December 2024
Department of Neurosurgery, Radboud University Medical Center, Nijmegen, the Netherlands.
Research Question: The goal of this study was to assess the diagnostic accuracy of spinal time-resolved contrast-enhanced MR angiography (4D-MRA) for the detection and localization of spinal dural arteriovenous fistulas (SDAVF) in our institution.
Material And Methods: Single center retrospective cohort study of patients with the clinical suspicion of a SDAVF. Patients were included who had undergone spinal 4D-MRA in the period January 2010-February 2021.
Heliyon
January 2025
Department of Energy System Engineering, Faculty of Mechanical Engineering, K.N. Toosi University of Technology, No. 15, Pardis St., Molasadra Ave., Vanak Sq., Tehran, Iran.
The rising global demand for air conditioning systems, driven by increasing temperatures and urbanization, has led to higher energy consumption and greenhouse gas emissions. HVAC systems, particularly AC, account for nearly half of building energy use, highlighting the need for efficient cooling solutions. Passive cooling, especially radiative cooling, offers potential to reduce cooling loads and improve energy efficiency.
View Article and Find Full Text PDFBMC Cancer
January 2025
Department of Ultrasonography, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital, Fuzhou, 350014, China.
Background: Accurate identification of small metastatic lymph nodes (LNs) remains a significant challenge with conventional ultrasound (US) due to its limitations in sensitivity for smaller LNs. The use of contrast-enhanced ultrasound (CEUS), especially with perfluorobutane in the postvascular phase of CEUS, may improve the diagnosis of metastatic LNs in cancer patients. We sought to investigate the diagnostic accuracy of the postvascular phase of CEUS with perfluorobutane in identifying suspected small cervical LNs in cancer patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!