A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of multiple stapler firings used for rectal division on colorectal anastomotic leak rate. | LitMetric

Background: Anastomotic leakage following colorectal resection remains one of the most significant complications with relevant morbidity and mortality. There is evidence that a higher number of stapler firings for rectal division can affect the leak rate in double stapling anastomosis. However, there are no data concerning compression anastomosis. We present our institutional experience addressing this issue.

Design: This is a retrospective review of a prospective institutional database of patients undergoing colonic and rectal resection for benign and malignant indications between January 2008 and December 2014 at the surgical department of the St. John of God Hospital, Vienna. Inclusion criteria were rectal division with linear stapling devices and construction of anastomosis to the rectal stump using a circular stapler or compression device.

Results: Three hundred eighty two (196 female; 51.3%) patients were included. Mean age was 65.8 years (range: 18-95) Indications for the operation included diverticular disease (44.8%), colorectal carcinoma (51.6%), inflammatory bowel disease (1.8%), and adenoma (1.8%). A laparoscopic approach was employed in 334 cases (87.4%); in 170 patients (44.9%), a compression anastomosis was created. One, two, and three or more stapler cartridges were used for rectal division in 58.4, 33.5, and 8.1%, respectively. Male gender, neoadjuvant therapy, rectal cancer as an underlying disease, laparoscopic surgical approach, and duration of operation longer than 200 min are leading causes for the usage of more than one stapler cartridge. Overall leak rate was 4.7% (18/382). The only factor associated with the occurrence of leakage was the use of three or more stapler cartridges for the closure of the rectal stump (p = 0.002).

Conclusion: Our data support that multiple stapler firings for rectal division following colorectal resection has a major impact on anastomotic leak rate. Especially in laparoscopic surgery efforts should be made to minimize the number of stapler cartridges used.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5715046PMC
http://dx.doi.org/10.1007/s00464-017-5611-0DOI Listing

Publication Analysis

Top Keywords

rectal division
20
leak rate
16
stapler firings
12
firings rectal
12
stapler cartridges
12
rectal
9
stapler
8
multiple stapler
8
division colorectal
8
anastomotic leak
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!