A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effects of hip abduction on sciatic nerve biomechanics during terminal hip flexion. | LitMetric

Terminal hip flexion contributes to increased strain in peripheral nerves at the level of the hip joint. The effects of hip abduction and femoral version on sciatic nerve biomechanics are not well understood. A decrease in sciatic nerve strain will be observed during terminal hip flexion and hip abduction, independent of femoral version. Six un-embalmed human cadavers were utilized. Three Differential Variable Reluctance Transducers (DVRTs) sensors were placed on the sciatic nerve while the leg was flexed to 70° with a combination of - 10°, 0°, 20° and 40° adduction/abduction. DVRT placement included: (i) under piriformis, (ii) immediately distal to the gemelli/obturator, (iii) four centimeters distal to sensor two. A de-rotational osteotomy to decrease femoral version 10° was performed, and sciatic nerve strain was measured by the same procedure. Data were analyzed with three-way analysis of variance and Bonferroni analysis to identify differences in the mean values of sciatic nerve strain between native and decreased version state, hip abduction angle and DVRT sensor location. Significant main effects were observed for femoral version ( = 0.04) and DVRT sensor location ( = 0.01). Sciatic nerve strain decreased during terminal hip flexion and abduction in the decreased version state. An 84.23% decrease in sciatic nerve strain was observed during hip abduction from neutral to 40° in the presence of decreased version at terminal hip flexion. The results obtained from this study confirm the role of decreased femoral version and hip abduction at terminal hip flexion to decrease the strain in the sciatic nerve.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5467418PMC
http://dx.doi.org/10.1093/jhps/hnx008DOI Listing

Publication Analysis

Top Keywords

sciatic nerve
36
hip abduction
24
terminal hip
24
hip flexion
24
femoral version
20
nerve strain
20
hip
12
decreased version
12
sciatic
9
nerve
9

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!