This study examined the timing of spontaneous self-monitoring in the naming responses of people with aphasia. Twelve people with aphasia completed a 615-item naming test twice, in separate sessions. Naming attempts were scored for accuracy and error type, and verbalizations indicating detection were coded as negation (e.g., "no, not that") or repair attempts (i.e., a changed naming attempt). Focusing on phonological and semantic errors, we measured the timing of the errors and of the utterances that provided evidence of detection. The effects of error type and detection response type on error-to-detection latencies were analyzed using mixed-effects regression modeling. We first asked whether phonological errors and semantic errors differed in the timing of the detection process or repair planning. Results suggested that the two error types primarily differed with respect to repair planning. Specifically, repair attempts for phonological errors were initiated more quickly than repair attempts for semantic errors. We next asked whether this difference between the error types could be attributed to the tendency for phonological errors to have a high degree of phonological similarity with the subsequent repair attempts, thereby speeding the programming of the repairs. Results showed that greater phonological similarity between the error and the repair was associated with faster repair times for both error types, providing evidence of error-to-repair priming in spontaneous self-monitoring. When controlling for phonological overlap, significant effects of error type and repair accuracy on repair times were also found. These effects indicated that correct repairs of phonological errors were initiated particularly quickly, whereas repairs of semantic errors were initiated relatively slowly, regardless of their accuracy. We discuss the implications of these findings for theoretical accounts of self-monitoring and the role of speech error repair in learning.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5536244PMC
http://dx.doi.org/10.1016/j.cortex.2017.05.008DOI Listing

Publication Analysis

Top Keywords

repair attempts
16
semantic errors
16
phonological errors
16
repair
12
error type
12
error types
12
errors initiated
12
errors
10
timing spontaneous
8
spontaneous self-monitoring
8

Similar Publications

Outcome of Recurrent Tracheoesophageal Fistula Treatment After Esophageal Atresia Repair.

J Pediatr Surg

January 2025

Congenital Oesophageal and Airway Team Utrecht, Departments of Paediatric Surgery and Otorhinolaryngology and Head and Neck Surgery, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, the Netherlands.

Introduction: Recurrent Tracheoesophageal Fistula (rTEF) is a complication of Esophageal Atresia (EA) that can lead to severe respiratory symptoms. RTEF can be corrected via endotracheal treatment (ET) or surgical treatment (ST). The efficacy of these techniques varies in literature.

View Article and Find Full Text PDF

Unlabelled: Wound debridement is commonplace in expediting wound healing in the clinic. Despite this, there are limited resources available for simulation training for practitioners prior to facing real-life patients. Typically, citrus peels or porcine skin are employed in a vain attempt to improve debridement proficiency, yet these fail to provide a realistic experience of the textures and consistencies of wounds.

View Article and Find Full Text PDF

Tissue selective ultrasonic debridement is a new method of debriding chronic wounds that prepares the wound for advanced tissue application. This article presents the case of an 89-year-old woman with a chronic nonhealing wound to her lateral distal leg. The wound had a significant amount of biofilm and fibrous slough.

View Article and Find Full Text PDF

Purpose The purpose of this study was to evaluate the ability of a Chat Generative Pre-trained Transformer (ChatGPT) to provide academic answers to frequently asked questions using a comparison with Google web search FAQs and answers. This study attempted to determine what patients ask on Google and ChatGPT and whether ChatGPT and Google provide factual information for patients about arthroscopic meniscus repair. Method A cleanly installed Google Chrome browser and ChatGPT were used to ensure no individual cookies, browsing history, other side data, or sponsored sites.

View Article and Find Full Text PDF

In-vitro and in-vivo studies of Tridax procumbens leaf extract incorporated bilayer polycaprolactone/polyvinyl alcohol-chitosan electrospun nanofiber for wound dressing application.

Int J Biol Macromol

January 2025

Department of Physics, Amrita School of Physical Sciences, Coimbatore, Amrita Vishwa Vidyapeetham, India; Biomaterials Laboratory, Amrita School of Engineering, Coimbatore, Amrita Vishwa Vidyapeetham, India. Electronic address:

This study was an attempt to fabricate an antibacterial wound dressing, which was a bilayered polycaprolactone / polyvinyl alcohol-chitosan (PCL/PVA-CS) nanofibrous membrane. Entrapping ethanolic leaf extract of Tridax procumbens L. (PCL/PVA-CS/Tp).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!