AI Article Synopsis

  • The study analyzed the long-term incidence of atrial fibrillation (AF) in patients who suffered a cryptogenic stroke (CS) and received an insertable cardiac monitor (ICM) for detection.
  • Over a two-year follow-up, the AF detection rate was found to be 21.5%, with episodes detected in about 238 out of 1247 patients.
  • Continuous monitoring with ICMs proved significantly more effective than traditional intermittent monitoring methods for detecting AF, highlighting the importance of ICMs in managing CS patients.

Article Abstract

Background: The long-term incidence of atrial fibrillation (AF) in cryptogenic stroke (CS) patients has been explored in carefully controlled clinical trials but real-world data are limited. We investigated the two-year incidence of AF in real-world clinical practice among a large cohort of patients with an insertable cardiac monitor (ICM) placed for AF detection following CS.

Methods: Patients in the de-identified Medtronic Discovery™ Link database who received an ICM (Reveal LINQ™) for the purpose of AF detection following CS were included and monitored for up to 2years. All detected AF episodes (≥2min) were adjudicated. We quantified the AF detection rate using Kaplan-Meier survival estimates, analyzed the median time to initial detection of AF, and simulated the ability of various intermittent monitoring strategies to detect AF.

Results: A total of 1247 patients (65.3±13.0years, 53% male) were included and followed for 579±222days. AF episodes (n=4183) were detected in 238 patients, resulting in an AF detection rate of 21.5% at 2years. The median time to AF detection was 112 [IQR 35-293] days. Intermittent monitoring for AF detection was inferior to continuous ICM monitoring with sensitivities ranging from 2.9% (annual 24-hour Holter) to 29.9% (quarterly 7-day Holters), p<0.001.

Conclusions: AF episodes were detected via continuous monitoring with ICMs in approximately 1 of every 5 CS patients within 2years of follow-up. The vast majority of patients with AF would not have been detected with conventional external ambulatory monitors. ICMs should therefore be considered in the evaluation of CS patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2017.06.039DOI Listing

Publication Analysis

Top Keywords

atrial fibrillation
8
insertable cardiac
8
cryptogenic stroke
8
detection rate
8
median time
8
intermittent monitoring
8
detection
7
patients
5
long-term detection
4
detection atrial
4

Similar Publications

Introduction: The efficacy and safety of statins for secondary prevention in patients who have experienced a cardioembolic stroke are not well-defined. However, previous observational data reported hyperlipidemia as a risk factor for both ischemic and bleeding complications in patients with AF and previous stroke. Based on these premises, we conducted a sub-analysis of the RAF and RAF-NOAC studies to evaluate the efficacy and safety of statins in secondary prevention in patients with acute ischemic stroke and AF.

View Article and Find Full Text PDF

Lipoprotein(a) and Atrial Fibrillation: Mechanistic Insights and Therapeutic Approaches.

Int J Med Sci

January 2025

Department of Cardiology, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, People's Republic of China.

Elevated lipoprotein(a) [Lp(a)] levels are increasingly recognized as a significant risk factor for cardiovascular diseases and may also contribute to atrial fibrillation (AF). This review investigated the indirect mechanisms through which Lp(a) may influence AF, including proatherogenic, prothrombotic, and proinflammatory pathways. Traditional lipid-lowering therapies, such as lifestyle modifications and statins, have limited effects on Lp(a) levels.

View Article and Find Full Text PDF

Comparison of Catheter Ablation in Patients with Paroxysmal Non-valvular Atrial Fibrillation and Heart Failure with Preserved Ejection Fraction.

Int J Med Sci

January 2025

Department of Cardiology, The Second Xiangya Hospital, Central South University, Changsha 410011, Hunan Province, People's Republic of China.

The efficacy of radiofrequency ablation (RFA) in patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) has been established, but the efficacy and safety of cryoballoon ablation (CBA) and pulsed field ablation (PFA) remain unclear. This retrospective cohort study included 223 patients with paroxysmal non-valvular AF and HFpEF who underwent their first AF ablation between January 2017 and December 2021 and were divided into RFA (n = 77), CBA (n = 127), and PFA (n = 19) groups. After a mean follow-up of 11.

View Article and Find Full Text PDF

Background Atrial high-rate episodes (AHREs) detected by cardiac implantable electronic devices (CIEDs) are indicative of future clinical atrial fibrillation (AF) and stroke risk. This study aimed to investigate the prevalence of AHREs among Thai patients with CIED implantation and identify associated risk factors. Methods A retrospective observational study enrolled 278 CIED patients with AHREs lasting five minutes to 24 hours, with an average atrial rate ≥ 175 bpm, excluding known clinical AF at device implantation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!