The aim of this study was to improve and validate a more stable and less time-consuming method based on liquid chromatography and tandem mass spectrometry (LC- MS/MS) for the quantitative measurement of imatinib and its metabolite N-demethyl-imatinib (NDI) in human plasma. Separation of analytes was performed on a Waters XTerra RP column (50 × 2.1 mm i.d., 3.5 μm) with a mobile phase consisting of methanol-acetonitrile-water (65:20:15, v/v/v) with 0.05% formic acid at a flow-rate of 0.2 mL/min. The Quattro MicroTM triple quadruple mass spectrometer was operated in the multiple-reaction-monitoring mode via positive electrospray ionization interface using the transitions m/z 494.0 → 394.0 for imatinib, m/z 479.6 → 394.0 for NDI and m/z 488.2 → 394.0 for IS. The method was linear over 0.01-10 μg/mL for imatinib and NDI. The intra- and inter-day precisions were all <15% in terms of relative standard deviation, and the accuracy was within ±15% in terms of relative error for both imatinib and NDI. The lower limit of quantification was identifiable and reproducible at 10 ng/mL. The method was sensitive, specific and less time-consuming and it was successfully applied in gastrointestinal stromal tumor patients treated with imatinib.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bmc.4022DOI Listing

Publication Analysis

Top Keywords

metabolite n-demethyl-imatinib
8
human plasma
8
mass spectrometry
8
simultaneous quantification
4
imatinib
4
quantification imatinib
4
imatinib main
4
main metabolite
4
n-demethyl-imatinib human
4
plasma liquid
4

Similar Publications

Can therapeutic drug monitoring increase the safety of Imatinib in GIST patients?

Cancer Med

February 2018

Institute of Clinical Pharmacology, School of Pharmaceutical Sciences, Sun Yat-Sen University, Guangzhou, 510006, China.

Imatinib at 400 mg daily is the standard treatment for patients affected with CML and GIST. The intervariability in plasma concentration is very significant. In many reports, a good therapeutic effect is attributed to an adequate concentration of Imatinib.

View Article and Find Full Text PDF

The aim of this study was to improve and validate a more stable and less time-consuming method based on liquid chromatography and tandem mass spectrometry (LC- MS/MS) for the quantitative measurement of imatinib and its metabolite N-demethyl-imatinib (NDI) in human plasma. Separation of analytes was performed on a Waters XTerra RP column (50 × 2.1 mm i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!