Purpose: Respiratory motion can affect pharmacokinetic perfusion parameters quantified from liver dynamic contrast-enhanced MRI. Image registration can be used to align dynamic images after reconstruction. However, intra-image motion blur remains after alignment and can alter the shape of contrast-agent uptake curves. We introduce a method to correct for inter- and intra-image motion during image reconstruction.

Methods: Sixteen liver dynamic contrast-enhanced MRI examinations of nine subjects were performed using a golden-angle stack-of-stars sequence. For each examination, an image time series with high temporal resolution but severe streak artifacts was reconstructed. Images were aligned using region-limited rigid image registration within a region of interest covering the liver. The transformations resulting from alignment were used to correct raw data for motion by modulating and rotating acquired lines in k-space. The corrected data were then reconstructed using view sharing.

Results: Portal-venous input functions extracted from motion-corrected images had significantly greater peak signal enhancements (mean increase: 16%, t-test, P <  0.001) than those from images aligned using image registration after reconstruction. In addition, portal-venous perfusion maps estimated from motion-corrected images showed fewer artifacts close to the edge of the liver.

Conclusions: Motion-corrected image reconstruction restores uptake curves distorted by motion. Motion correction also reduces motion artifacts in estimated perfusion parameter maps. Magn Reson Med 79:1345-1353, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5747555PMC
http://dx.doi.org/10.1002/mrm.26782DOI Listing

Publication Analysis

Top Keywords

golden-angle stack-of-stars
8
liver dynamic
8
dynamic contrast-enhanced
8
contrast-enhanced mri
8
image registration
8
intra-image motion
8
image
5
rigid-body motion
4
motion correction
4
liver
4

Similar Publications

Combination of deep learning reconstruction and quantification for dynamic contrast-enhanced (DCE) MRI.

Magn Reson Imaging

December 2024

Weill Cornell Graduate School of Medical Sciences, New York, NY, United States; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, United States; Department of Radiology, Memorial Sloan Kettering Cancer Center, NY, New York, USA. Electronic address:

Dynamic contrast-enhanced (DCE) MRI is an important imaging tool for evaluating tumor vascularity that can lead to improved characterization of tumor extent and heterogeneity, and for early assessment of treatment response. However, clinical adoption of quantitative DCE-MRI remains limited due to challenges in acquisition and quantification performance, and lack of automated tools. This study presents an end-to-end deep learning pipeline that exploits a novel deep reconstruction network called DCE-Movienet with a previously developed deep quantification network called DCE-Qnet for fast and quantitative DCE-MRI.

View Article and Find Full Text PDF

Purposes: To enhance the functional capability of MRI, this study aims to develop a novel MR elastography (MRE) sequence that achieves rapid acquisition without distortion artifacts.

Methods: A displacement-encoded stimulated echo (DENSE) with multiphase acquisition scheme was used to capture wave images. A center-out golden-angle stack-of-stars sampling pattern was introduced for improved SNR and data incoherence.

View Article and Find Full Text PDF

MRI of GlycoNOE in the human liver using GraspNOE-Dixon.

Magn Reson Med

February 2025

BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, New York, USA.

Purpose: The objective of this study was to develop a new MRI technique for non-invasive, free-breathing imaging of glycogen in the human liver using the nuclear Overhauser effect (NOE).

Methods: The proposed method, called GraspNOE-Dixon, uses a novel MRI sequence that combines steady-state saturation-transfer preparation with multi-echo golden-angle radial stack-of-stars sampling. Multi-echo acquisition enables fat/water-separated imaging for quantification of water-specific NOE.

View Article and Find Full Text PDF

Purpose: To develop a highly accelerated non-contrast-enhanced 4D-MRA technique by combining stack-of-stars golden-angle radial acquisition with a modified self-calibrated low-rank subspace reconstruction.

Methods: A low-rank subspace reconstruction framework was introduced in radial 4D MRA (SUPER 4D MRA) by combining stack-of-stars golden-angle radial acquisition with control-label k-space subtraction-based low-rank subspace modeling. Radial 4D MRA data were acquired and reconstructed using the proposed technique on 12 healthy volunteers and 1 patient with steno-occlusive disease.

View Article and Find Full Text PDF

Respiratory motion-induced image blurring and artifacts can compromise image quality in dynamic contrast-enhanced MRI (DCE-MRI) of the liver. Despite remarkable advances in respiratory motion detection and compensation in past years, these techniques have not yet seen widespread clinical adoption. The accuracy of image-based motion detection can be especially compromised in the presence of contrast enhancement and/or in situations involving deep and/or irregular breathing patterns.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!