A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Removal of potentially toxic elements from aqueous solutions and industrial wastewater using activated carbon. | LitMetric

Water contamination with potentially toxic elements (PTEs) has become one of the key issues in recent years that threatens human health and ecological systems. The present study is aimed at removing PTEs like cadmium (Cd), chromium (Cr), copper (Cu) and lead (Pb) from aqueous solutions and industrial wastewater using activated carbon (AC) as an adsorbent through different batch and column experiments. Results demonstrated that the removal of PTEs from aqueous solutions was highly pH dependent, except for Cr, and the maximum removal (>78%) was recorded at pH 6.0. However, maximum Cr removal (82.8%) was observed at pH 3.0. The adsorption reached equilibrium after 60 min with 2 g of adsorbent. Coefficient (R) values suggested by the Langmuir isotherm model were 0.97, 0.96, 0.93 and 0.95 for Cd, Cr, Cu and Pb, respectively, indicating the fit to this model. In column experiments, the maximum removal of PTEs was observed at an adsorbent bed height of 20 cm with the optimal flow rate of 3.56 mL/min. Furthermore, PTEs removal by AC was observed in the order of Cu > Cd > Pb > Cr. Findings from this study suggest that AC could be used as a promising adsorbent for simultaneously removing several PTEs from wastewaters.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2017.130DOI Listing

Publication Analysis

Top Keywords

aqueous solutions
12
maximum removal
12
toxic elements
8
solutions industrial
8
industrial wastewater
8
wastewater activated
8
activated carbon
8
removing ptes
8
column experiments
8
removal ptes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!