Purpose: To evaluate the effect of bimatoprost/timolol maleate fixed combination (BTFC), latanoprost/timolol maleate fixed combination (LTFC), and travoprost/timolol maleate fixed combination (TTFC) on 24-h intraocular pressure (IOP) in patients with open-angle glaucoma.
Methods: This prospective, observer-masked, randomized study included 50 patients with primary open-angle glaucoma. All patients were using hypotensive lipids and timolol maleate fixed combination treatment for ≥4 weeks and had an IOP ≤ 21 mmHg. Group 1 (n = 18) received BTFC, group 2 (n = 14) received LTFC, and group 3 (n = 18) received TTFC. All patients were hospitalized, and IOP was monitored for 24-h (10:00, 14:00, 18:00, 22:00, 02:00, and 06:00). Mean diurnal IOP variation measurements were taken between 06:00 and 18:00, and mean nocturnal IOP variation measurements were taken between 22:00 and 02:00. Mean IOP and IOP variation in the three groups were compared.
Results: Mean 24-h IOP did not differ significantly between the three groups (group 1: 14.6 ± 2.9 mmHg; group 2: 14.1 ± 3.7 mmHg and group 3: 15.8 ± 2.0 mmHg; P > 0.05). Mean diurnal IOP variation was 4.6 ± 2.3 mmHg in group 1, 5.8 ± 2.4 mmHg in group 2, and 4.3 ± 1.7 mmHg in group 3, and mean nocturnal IOP variation was 3.2 ± 2.8 mmHg in group 1, 2.9 ± 1.9 mmHg in group 2, and 3.0 ± 1.6 mmHg group 3. There were not any significant differences in diurnal or nocturnal IOP variation between the three groups (P < 0.05).
Conclusion: All three fixed combinations effectively controlled IOP for 24-h and had a similar effect on diurnal and nocturnal IOP variations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10792-017-0601-8 | DOI Listing |
Croat Med J
December 2024
Marijan Klarica, Department of Pharmacology and Croatian Institute for Brain Research, University of Zagreb School of Medicine, Šalata 3b, 10000 Zagreb, Croatia,
It is generally accepted that intraocular pressure (IOP) depends on the rate of aqueous humor production, system outflow resistance, and episcleral venous pressure. Therefore, control IOP values are expected to be within the strict and predictable limits in specific animal species, and there should be no vast differences between species. However, in the literature the control IOP values significantly vary (from potentially "hypotensive" to "hypertensive") within the same species, and especially between species depending on the measurement technique, head position in relation to the rest of the body, circadian rhythm, age, and topical and systemic drugs (anesthetics) applied.
View Article and Find Full Text PDFBackground: The Global Burden of Diseases, Injuries, and Risk Factors Study (GBD) 2021 provides a comprehensive assessment of health and risk factor trends at global, regional, national, and subnational levels. This study aims to examine the burden of diseases, injuries, and risk factors in the USA and highlight the disparities in health outcomes across different states.
Methods: GBD 2021 analysed trends in mortality, morbidity, and disability for 371 diseases and injuries and 88 risk factors in the USA between 1990 and 2021.
Comput Methods Programs Biomed
November 2024
Department of Ophthalmology, Boston University School of Medicine, Boston, MA, United States; Department of Anatomy and Neurobiology, Boston University School of Medicine, Boston, MA, United States.
Background And Objective: The conventional aqueous outflow pathway, which includes the trabecular meshwork (TM), juxtacanalicular tissue (JCT), and inner wall endothelium of Schlemm's canal (SC) and its basement membrane, plays a significant role in regulating intraocular pressure (IOP) by controlling aqueous humor outflow resistance. Despite its significance, the biomechanical and hydrodynamic properties of this region remain inadequately understood. Fluid-structure interaction (FSI) and computational fluid dynamics (CFD) modeling using high-resolution microstructural images of the outflow pathway provides a comprehensive method to estimate these properties under varying conditions, offering valuable understandings beyond the capabilities of current imaging techniques.
View Article and Find Full Text PDFOphthalmic Physiol Opt
December 2024
École d'optométrie, Université de Montréal, Montreal, Quebec, Canada.
Purpose: The present study aimed to determine the potential impact of scleral lenses on intraocular pressure (IOP) by analysing the Bruch's membrane opening-minimum rim width (BMO-MRW) while the lenses are worn, in a population with keratoconus.
Methods: Participants were required to have keratoconus and be successfully fitted with scleral lenses for at least 3 months. A new pair of optimised scleral lenses was provided before the study.
Heliyon
November 2024
Department of Ophthalmology, Daping Hospital of Army Medical University, PLA, Chongqing, 400042, China.
Objective: To investigate the clinical effect and safety of Implantable Collamer Lens (ICL) implantation in myopic patients with relatively shallow anterior chamber depth (ACD).
Methods: Retrospective analysis, comparative, non-interventional case series. Patients with myopia who underwent ICL implantation were included in the study and were categorized into two groups: one with a relatively shallow ACD (2.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!