Quantifying changes in blood chemistry in elasmobranchs can provide insights into the physiological insults caused by anthropogenic stress, and can ultimately inform conservation and management strategies. Current methods for analysing elasmobranch blood chemistry in the field are often costly and logistically challenging. We compared blood pH values measured using a portable, waterproof pH meter (Hanna Instruments HI 99161) with blood pH values measured by an i-STAT system (CG4+ cartridges), which was previously validated for teleost and elasmobranch fishes, to gauge the accuracy of the pH meter in determining whole blood pH for the Cuban dogfish () and lemon shark (). There was a significant linear relationship between values derived the pH meter and the i-STAT for both species across a wide range of pH values and temperatures (Cuban dogfish: 6.8-7.1 pH 24-30°C; lemon sharks: 7.0-7.45 pH 25-31°C). The relative error in the pH meter's measurements was ~±2.7%. Using this device with appropriate correction factors and consideration of calibration temperatures can result in both a rapid and accurate assessment of whole blood pH, at least for the two elasmobranch species examined here. Additional species should be examined in the future across a wide range of temperatures to determine whether correction factors are universal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5463720PMC
http://dx.doi.org/10.1093/conphys/cox012DOI Listing

Publication Analysis

Top Keywords

portable waterproof
8
blood chemistry
8
blood values
8
values measured
8
cuban dogfish
8
wide range
8
correction factors
8
species examined
8
blood
7
validation portable
4

Similar Publications

Ion beam therapy techniques have advanced significantly in the past two decades. However, the development of dosimetric verification methods has lagged. Traditional dosimetry, which offers a macroscopic view of the absorbed dose, fails to address the micrometric-scale stochastic effects crucial for understanding biological responses.

View Article and Find Full Text PDF

Metal-organic framework-based SERS chips enable in situ and sensitive detection of dissolved hydrogen sulfide in natural water: Towards a bring-back-chip mode for field analysis.

J Hazard Mater

December 2024

CAS Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China; Center for Ocean Mega-Science, Chinese Academy of Sciences, 266071 Qingdao, China. Electronic address:

Hydrogen sulfide (HS) in natural water plays an important role in carbon and sulfur cycles in biosphere. Current detection protocol is complicated, which need to "bring back water" to lab followed by gas chromatograph analysis. In situ, field detection is still challenging.

View Article and Find Full Text PDF

Energy harvesting from ubiquitous natural water vapor based on moisture electric generator (MEG) technology holds great potential to power portable electronics, the Internet of Things, and wireless transmission. However, most devices still encounter challenges of low output, and a single MEG complemented with another form of energy harvesting for achieving high power has seldom been demonstrated. Herein, we report a flexible and efficient hybrid generator capable of harvesting moisture and tribo energies simultaneously, both from the source of water droplets.

View Article and Find Full Text PDF

A thermoelectric generator (TEG) is one of the important energy harvesting sources for wearable electronic devices, which converts waste heat into electrical energy without any external stimuli, such as light or mechanical motion. However, the poor flexibility of traditional TEGs (e.g.

View Article and Find Full Text PDF

Open-source devices are nowadays used in a vast number of research fields like medicine, education, agriculture, and sports, among others. In this work, an open-source, portable, low-cost pH logger, appropriate for in situ measurements, was designed and developed to assist in experiments on agricultural produce manufacturing. Τhe device was calibrated manually using pH buffers for values of 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!