The objectives of this study were to test the effect of interaction device on performance in a process control task (managing a tank farm). The study compared the following two conditions: a) 4K-resolution 55" screen with a 21" touchscreen versus b) 4K-resolution 55″ screen with keyboard/mouse. The touchscreen acted both as an interaction device for data entry and navigation and as an additional source of information. A within-subject experiment was conducted among 20 college engineering students. A primary task of preventing tanks from overfilling as well as a secondary task of manual logging with situation awareness questions were designed for the study. Primary Task performance (including tank level at discharge, number of tank discharged and performance score), Secondary Task Performance (including Tank log count, performance score), system interaction times, subjective workload, situation awareness questionnaire, user experience survey regarding usability and condition comparison were used as the measures. Parametric data resulted in two metrics statistically different means between the two conditions: The 4K-keyboard condition resulted in faster Detection + Navigation time compared to the 4K-touchscreen condition, by about 2 s, while participants within the 4K-touchscreen condition were about 2 s faster in data entry than in the 4K-keyboard condition. No significant results were found for: performance on the secondary task, situation awareness, and workload. Additionally, no clear significant differences were found in the non-parametric data analysis. However, participants showed a slight preference for the 4K-touchscreen condition compared to the 4K-keyboard condition in subjective responses in comparing the conditions. Introducing the touchscreen as an additional/alternative input device showed to have an effect in interaction times, which suggests that proper design considerations need to be made. While having values shown on the interaction device provides value, a potential issue of visual distraction exists when having an additional visual display. The allocation of visual attention between primary displays and the touchscreen should be further investigated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.apergo.2017.04.015 | DOI Listing |
Front Bioeng Biotechnol
January 2025
Federal University of Alagoas, Center of Technology, Maceió, Brazil.
Medical implants are designed to replace missing parts or improve body functions and must be capable of providing structural support or therapeutic intervention for a medical condition. Advances in materials science have enabled the development of devices made from metals, polymers, bioceramics, and composites, each with its specific advantages and limitations. This review analyzes the incorporation of biopolymers, proteins, and other biomacromolecules into implants, focusing on their role in biological integration and therapeutic functions.
View Article and Find Full Text PDFRSC Adv
January 2025
Département de Chimie, Faculté des Sciences et de Génie, Université Laval Québec QC G1V 0A6 Canada.
Blood carries some of the most valuable biomarkers for disease screening as it interacts with various tissues and organs in the body. Human blood serum is a reservoir of high molecular weight fraction (HMWF) and low molecular weight fraction (LMWF) proteins. The LMWF proteins are considered disease marker proteins and are often suppressed by HMWF proteins during analysis.
View Article and Find Full Text PDFProc ACM Interact Mob Wearable Ubiquitous Technol
March 2022
Northeastern University, Boston, MA.
Ecological momentary assessment (EMA) is used to gather self-report on behaviors using mobile devices. Microinteraction EMA (μEMA), is a type of EMA where each survey is that can be answered with a glanceable microinteraction on a smartwatch. Prior work shows that even when μEMA interrupts far more frequently than smartphone-EMA, μEMA yields higher response rates with lower burden.
View Article and Find Full Text PDFACS Cent Sci
January 2025
The Second Affiliated Hospital of Zhejiang University School of Medicine, Life Sciences Institute, Zhejiang University, Hangzhou 310058, China.
Genetic encoding of noncanonical amino acids (ncAAs) with desired functionalities is an invaluable tool for the study of biological processes and the development of therapeutic drugs. However, existing ncAA incorporation strategies are rather time-consuming and have relatively low success rates. Here, we develop a virtual ncAA screener based on the analysis and modeling of the chemical properties of all reported ncAA substrates to virtually determine the recognition potential of candidate ncAAs.
View Article and Find Full Text PDFPeerJ
January 2025
College of Engineering, University of Tennessee - Knoxville, TN, United States of America.
Objective: The purpose of this study was to investigate the timing and mode of failure of metallic screw-type suture anchors used to attach artificial tendons to bone in an New Zealand White rabbit model.
Study Design: Metal suture anchors with braided composite sutures of varying sizes (United States Pharmacopeia (USP) size 1, 2, or 5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 female New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement, = 8), or four/five weeks after (delayed replacement, = 4) resection of the biological tendon.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!