Hearing Preservation: Does Electrode Choice Matter?

Otolaryngol Head Neck Surg

1 Department of Otolaryngology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.

Published: November 2017

Objective Evaluate if electrode design affects hearing preservation (HP) following cochlear implantation (CI) with full-length electrodes. Study Design Case series with chart review. Setting Tertiary referral academic center. Subjects and Methods Forty-five adults with low-frequency hearing (≤85 dB at 250 and 500 Hz) who underwent unilateral CI with full-length electrode arrays made by 1 manufacturer were included. HP was calculated with (1) mean low-frequency pure-tone average (LFPTA) at 250 and 500 Hz (MEAN method), (2) a percentile method across the audiometric frequency spectrum generating an S-value (HEARRING method), and (3) functional if hearing remained ≤85 dB at 250 and 500 Hz. Audiometric testing was performed approximately 1 month and 1 year postoperatively, yielding short-term and long-term results, respectively. Results Of 45 patients who underwent CI, 46.7% received lateral wall (LW) and 53.3% received perimodiolar (PM) electrodes. At short-term follow-up, LW electrodes were associated with significantly better HP than PM (LFPTA method: 27.7 vs 39.3 dB, P < .05; S-value method: 48.2 vs 21.8%, P < .05). In multivariate regression of short-term outcomes, LW electrode use was a significant predictor of better HP ( P < .05). At long-term follow-up, electrode type was not associated with HP. Younger patient age was the only significant predictor of long-term HP on multivariate analysis ( P < .05). Conclusion The LW electrode is associated with short-term HP, suggesting its design is favorable for limiting trauma to the cochlea during and directly following CI. Other factors, including age, are relevant for maintaining HP over the long term. The data support further investigation into what modifiable factors may promote long-term HP.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0194599817707167DOI Listing

Publication Analysis

Top Keywords

250 500
12
hearing preservation
8
≤85 250
8
electrode
6
method
5
hearing
4
preservation electrode
4
electrode choice
4
choice matter?
4
matter? objective
4

Similar Publications

Two main aspects of the in vitro mouse foetal liver cell assay for Erythroid Stimulating Factor (ESF) in human sera have been investigated. The haem extraction process has been shown to give specific and quantitative recovery of 59Fe labelled haem from haemoglobin thus confirming that the material assayed in human sera is stimulating the synthesis of this protein. The extraction procedure can be simplified considerably by prior mixing of the reagents without significantly influencing the results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!