Aims: The aim of this study was to evaluate vascular complications using the "parallel suture technique" in patients receiving an Edwards SAPIEN XT (SXT) or SAPIEN S3 (S3) transcatheter heart valve (THV).

Methods And Results: Two hundred consecutive patients with symptomatic severe aortic stenosis treated with TF-TAVI were included in this study where the "parallel suture technique" was applied for vascular access-site closure. This was achieved by placing the sutures medial and lateral to the puncture site. Vascular access-site complications were defined as vascular dissection, perforation, obstruction, arteriovenous fistula or pseudoaneurysms, and classified according to the Valve Academic Research Consortium-2 (VARC-2) criteria. Duplex sonography was performed routinely in every patient. In patients receiving the S3, the sheath to femoral and iliac artery ratio was significantly lower than in the SXT group, reflecting reduction in sheath sizes for S3. More endovascular interventions were required after SXT implantation as compared to S3 (4% versus 1%, p=0.02). This was due to vascular obstruction or device failure. Moreover, increased life-threatening, major bleedings, and pseudoaneurysms were found in the SXT group (6% versus 1%, p=0.06, 13% versus 3%, p=0.009, 7% versus 1%, p=0.03, respectively).

Conclusions: The "parallel suture technique" using the ProGlide is associated with a low number of vascular complications, even when using larger sheath sizes.

Download full-text PDF

Source
http://dx.doi.org/10.4244/EIJ-D-16-01036DOI Listing

Publication Analysis

Top Keywords

"parallel suture
12
suture technique"
12
vascular complications
8
patients receiving
8
vascular access-site
8
sxt group
8
sheath sizes
8
vascular
7
parallel suture
4
suture technique
4

Similar Publications

Background: Air leakage during pulmonary resection is a major complication in thoracic surgery. It frequently occurs at sites of adhesion dissection, due to lung manipulation, and along the staple lines of automatic suturing devices, particularly in cases of pulmonary fragility such as those of emphysema and interstitial pneumonia. Persistent postoperative air leakage prolongs chest tube indwelling and extends hospitalization time.

View Article and Find Full Text PDF

Purpose: This study aims to compare the lateral brow-eyelid contour following traditional blepharoplasty versus blepharoplasty with brassiere sutures using 3D imaging.

Methods: This prospective, randomized, comparative, parallel-group trial involved 56 female patients with dermatochalasis. Patients with an odd number of letters in their first names underwent traditional upper blepharoplasty (group A), while the rest underwent blepharoplasty with orbicularis oculi muscle fixation (group B).

View Article and Find Full Text PDF

Arthroscopic V-Shaped Double-Pulley Suture-Bridge Repair of Massive Rotator Cuff Tear.

Arthrosc Tech

November 2024

The Second Affiliated Hospital, Department of Joint Surgery, Hengyang Medical School, University of South China, Hengyang, China.

At present, suture bridge is a feasible choice in the treatment of massive rotator cuff tears (MRCTs). However, high tension on the repair site and medial tension during suture tightening and after medial knotting are unavoidable problems in MRCT repair with a suture bridge. Arthroscopic V-shaped double-pulley suture-bridge repair is a pragmatic surgical technique for the repair of MRCTs.

View Article and Find Full Text PDF

Biomechanical performance of ATOZ expander: Finite-element analysis.

Am J Orthod Dentofacial Orthop

December 2024

Department of Mechanical, Materials and Aerospace Engineering, West Virginia University, Morgantown WVa. Electronic address:

Introduction: Microimplant-assisted rapid palatal expansion appliances have been used for the treatment of orthodontic patients with maxillary deficiency. A new design named ATOZ (applicable from A to Z) was recently introduced to expand the scope of treatment in early permanent dentition. The objective of this study was to analyze the biomechanical performance of the ATOZ expander with various microimplants configurations using finite-element method.

View Article and Find Full Text PDF

Purpose: To assess the variability in graft biomechanical properties of an acellular human dermal matrix patch.

Methods: A total of 22 strips obtained from 6 separate graft specimens (AlloPatch HD) were tested. Load elongation properties after cyclic loading, including ultimate load at break, energy at break, and extension at break, were tested and compared by graft thickness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!