Background: Percutaneous vertebroplasty has been widely applied in the treatment of osteoporotic vertebral compression fractures over the past two decades. However as one of the major complications, the rate of cement leakage seems not to be decreased significantly. In this study, the rate of cement leakage was compared between two groups using two different cement injection cannulas. The purpose was to determine the efficacy of side-opening cannula on preventing cement leakage in vertebroplasty for the treatment of osteoporotic vertebral compression fractures.
Methods: A retrospective study was conducted from January 2013 to December 2015. Totally 225 patients who received bilateral vertebroplasty due to osteoporotic vertebral compression fractures were included in the study. The patients were divided into test group who received vertebroplasty with side-opening cannulas and control group who received vertebroplasty with front-opening cannulas. The patients' medical records were reviewed to determine the bone marrow density, preoperative vertebral compression ratio, preoperative and postoperative VAS, operation time, volume of injected bone cement, rate of cement leakage. Post-operative X-rays and CT scans were utilized to assess the degree of Cement leakage. Comparisons between groups and clinical results on VAS in each group were analyzed with appropriate test.
Results: All the patients were performed successfully without symptomatic complications. The back pain was significantly relieved after operation in both groups (P < 0.05). At 6 days and 6 months follow-up, there was no significant difference in the mean VAS score between the two groups (P > 0.05). The rate of cement leakage in the test group was significantly lower than that in the control group (P < 0.05).
Conclusion: Percutaneous vertebroplasty with side-opening cannula is a safe and effective minimally invasive method in the treatment of osteoporotic vertebral compression fractures, the rate of cement leakage can be significantly reduced by redirecting the cement flow.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jos.2017.05.001 | DOI Listing |
Heliyon
January 2025
Department of Orthopedics, Beijing Friendship Hospital, Capital Medical University, Beijing, 100050, China.
Percutaneous vertebroplasty (PVP) is a widely utilized minimally invasive technique originally developed for the treatment of vertebral compression fractures. It has since expanded to treat osteoporotic vertebral compression fractures, pathologic vertebral fractures resulting from primary or secondary spinal tumors, and traumatic spinal fractures. Despite its benefits, PVP is associated with significant complications, the most common of which is bone cement leakage.
View Article and Find Full Text PDFJ Korean Neurosurg Soc
January 2025
Department of Neurosurgery, University of Opole, Opole, Poland.
Cement-augmented pedicle screw instrumentation is a widely accepted method for managing osteoporotic fractures, but it carries inherent risks, particularly related to cement leakage and embolism. This study aimed to analyze a clinical case of complications following cement fixation and provide a detailed review of relevant literature. A 70-year-old patient underwent transpedicular screw instrumentation from L2-L4 with polymethyl methacrylate augmentation, which resulted in cement leakage into the spinal canal and subsequent pulmonary embolism.
View Article and Find Full Text PDFPhotobiomodul Photomed Laser Surg
January 2025
Department of Preventive Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia.
Impact of surface conditioner phytic acid (IP6) Er,Cr:YSGG laser (ECYL) methylene blue photodynamic therapy (MB-PDT) on the microleakage and shear bond strength (SBS) of resin-modified glass ionomer cement (RMGIC) to primary sound dentin. Overall, 80 extracted sound primary molars were collected followed by their submergence in self-cure acrylic resin. The dentin surface was exposed and made flat and was assigned into four groups based on the surface conditioning.
View Article and Find Full Text PDFWorld Neurosurg
January 2025
Department of Orthopaedics, Binhai Hospital of Tianjin Medical University General Hospital, Tianjin 300480, China.
Background: This meta-analysis was conducted to compare the efficacy and safety of vertebral augmentation (VA) plus pedicle screw fixation (PSF) with VA for treating osteoporotic thoracolumbar fractures (OTLFs).
Methods: A comprehensive search was conducted in PubMed, Embase, Cochrane Library and China National Knowledge Infrastructure (CNKI) to identify studies comparing PSF+VA with VA for treating OTLF. The primary outcomes were operation time, blood loss, length of stay, visual analogue scale (VAS) score, Oswestry disability index (ODI), Cobb angle, anterior vertebral height (AVH), bone cement leakage, secondary fracture and other adverse events.
J Bone Joint Surg Am
January 2025
Department of Orthopaedics, BenQ Medical Center, The Affiliated BenQ Hospital of Nanjing Medical University, Nanjing, Jiangsu, People's Republic of China.
Background: No studies have evaluated the impact of the cement distribution as classified on the basis of the fracture bone marrow edema area (FBMEA) in magnetic resonance imaging (MRI) on the efficacy of percutaneous vertebral augmentation (PVA) for acute osteoporotic vertebral fractures.
Methods: The clinical data of patients with acute, painful, single-level thoracolumbar osteoporotic fractures were retrospectively analyzed. The bone cement distribution on the postoperative radiograph was divided into 4 types according to the distribution of the FBMEA on the preoperative MRI.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!