In the histopathological particle algorithm polyethylene (PE) particles with maximum lengths of more than 100μm - called PE supramacroparticles - are identified exclusively for knee joint and hip prostheses. However, a definitive characterisation, detection in all joint localisations and a causal clarification of the pathogenesis are lacking. In this study a total of 175 SLIM (synovial-like interface membrane) cases with PE supramacroparticles of knee joint prostheses (n=89), hip joint prostheses (n=44), ankle joint prostheses (n=36) and prostheses in three localisations of the upper extremities (n=6) were systematically investigated. The arithmetic mean of the particle length varied greatly within the prosthesis types. This had a significant positive correlation with the prosthesis lifetime and negative correlation with the date of implantation. It can be concluded that both the lifetime and the time of implantation have an influence on the particle length. The prostheses with supramacroparticulate damage moreover showed a clearly reduced survival rate compared with other data published on the prosthesis lifetime. The material wear therefore could not be attributed solely to the usual fatigue factors. Since loosening of the prostheses, decentring of the PE components or damage to the PE inlay existed in all cases, mechanical dysloading seems to be the most probable cause of PE supramacroparticle genesis. Due to the striking length and for demarcation from PE macroparticles, the term supramacroparticulate PE is proposed for a length of more than 100μm. In the extended histopathological particle algorithm supramacroparticulate PE has been included in the macroparticles category and should be taken into account and interpreted causally in histopathological diagnostics of joint prosthesis failure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prp.2017.03.014DOI Listing

Publication Analysis

Top Keywords

joint prostheses
12
histopathological particle
8
particle algorithm
8
knee joint
8
particle length
8
prosthesis lifetime
8
prostheses
7
joint
6
supramacroparticulate
4
supramacroparticulate joint
4

Similar Publications

Synovial fistula of the knee occurs when a defect in the joint capsule creates a connection between skin, bursa, and a near tissue, manifesting as an opening with continuous draining fluid or a cyst. This is a case of an 80-year-old male who developed a synovial fistula with cystic presentation 6 years after the primary total knee arthroplasty. Management included a total knee arthroplasty revision surgery with intraoperative identification of the fistula with methylene blue, and using a gelatin-thrombin matrix for closure.

View Article and Find Full Text PDF

Machine learning to predict periprosthetic joint infections following primary total hip arthroplasty using a national database.

Arch Orthop Trauma Surg

January 2025

Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, 55 Fruit Street, Boston, MA, 02114, USA.

Introduction: Periprosthetic joint infection (PJI) following total hip arthroplasty (THA) remains a devastating complication for patients and surgeons. Given the implications of these infections and the current paucity of risk calculators utilizing machine learning (ML), this study aimed to develop an ML algorithm that could accurately identify risk factors for developing a PJI following primary THA using a national database.

Materials And Methods: A total of 51,053 patients who underwent primary THA between 2013 and 2020 were identified using the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) database.

View Article and Find Full Text PDF

Case: A 75-year-old woman underwent cruciate retaining total knee arthroplasty (TKA) for osteonecrosis of the knee, converted from unicompartmental arthroplasty due to an intraoperative medial tibial plateau fracture. Four years later, she experienced persistent knee pain. Computed tomography revealed tibial malalignments in 2 planes.

View Article and Find Full Text PDF

Background: Total knee arthroplasty (TKA) is one of the most common orthopaedic procedures and the number of patients which undergo TKA will continue to rise in the coming years. Consecutively, the number of necessary revision surgeries will increase. One of the main reasons for revision surgery is aseptic loosening because of a so-called stress-shielding effect.

View Article and Find Full Text PDF

Temporal changes of tibial eminence after bi-cruciate retaining total knee arthroplasty.

BMC Musculoskelet Disord

January 2025

Department of Orthopaedic Surgery, Faculty of Medicine, The University of Tokyo, Tokyo City, Japan.

Background: Bicruciate-retaining (BCR) prostheses have been introduced to recreate normal knee movements by preserving both the anterior and posterior cruciate ligaments. One of the surgical procedures essential to the success of BCR total knee arthroplasty (TKA) is preservation of the tibial eminence. However, in our clinical experience, we found that a well-preserved tibial eminence changed its shape chronologically after the operation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!