Recurrent implantation failure is a pathology with a specific transcriptomic signature.

Fertil Steril

Department of Obstetrics and Gynecology, Zealand University Hospital and University of Copenhagen, Roskilde, Denmark. Electronic address:

Published: July 2017

Recurrent implantation failure (RIF) is a source of distress and frustration to both patients and their clinicians. In the absence of clinically useful tests, the therapeutic approach has been largely empirical, with limited efficacy. In recent years, new insights into the role of the endometrium in implantation have emerged, and a number of dysfunctions that may underlie implantation failure have been characterized. These point to the presence, in some patients, of an underlying endometrial pathology. In this article, the case is made that constitutive (rather than maturation) defects underlying RIF can be identified. Evidence is presented of a specific transcriptomic signature that is highly predictive of RIF.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.fertnstert.2017.05.028DOI Listing

Publication Analysis

Top Keywords

implantation failure
12
recurrent implantation
8
specific transcriptomic
8
transcriptomic signature
8
failure pathology
4
pathology specific
4
signature recurrent
4
failure rif
4
rif source
4
source distress
4

Similar Publications

The patient's mental health from the perspective of consultation-liaison psychiatry at the stage of qualification for mechanical circulatory support implantation.

Psychiatr Pol

October 2024

Śląskie Centrum Chorób Serca w Zabrzu; Katedra i Klinika Kardiochirurgii, Transplantologii, Chirurgii Naczyniowej i Endowaskularnej, Wydział Nauk Medycznych w Zabrzu, SUM w Katowicach.

During qualification for mechanical circulatory support, the comprehensive assessment of a patient's mental state is an integral element of the overall medical evaluation. It encompasses a range of psychosocial issues, and as such provides information helpful in the selection of a suitable candidate for the required treatment, and sometimes identifies contraindications to it. It allows ensuring that the patient meets expectations regarding both mental health stability and adherence to medical recommendations.

View Article and Find Full Text PDF

Left atrial shunting devices: why, what, how, and… when?

Heart Fail Rev

January 2025

Department of Cardiology, San Luca Hospital, IRCCS Istituto Auxologico Italiano, Milan, Italy.

Left atrial (LA) hypertension is central in the pathophysiology of heart failure (HF) in general and of HF with preserved ejection fraction (HFpEF) in particular. Despite approved treatments, a number of HF patients continue experiencing disabling symptoms due to LA hypertension, causing pulmonary congestion, pulmonary hypertension, and right heart dysfunction, at rest and/or during exercise. LA decompression therapies, i.

View Article and Find Full Text PDF

How to correct QT interval after cardiac resynchronisation therapy.

J Electrocardiol

January 2025

Victorian Heart Institute, Monash University, Clayton, VIC, Australia; Victorian Heart Hospital, Clayton, VIC, Australia. Electronic address:

Introduction: This study evaluates various formulae used to correct the QT interval in patients with wide QRS complexes to calculate corrected QT (QTc) following Cardiac Resynchronisation Therapy (CRT).

Methods: We included patients with severe heart failure and left bundle branch block, presenting with a QRS duration of at least 120 milliseconds, who underwent successful CRT implantation. Patients were excluded if they had non-lateral left ventricular lead placement, metabolic disorders, atrial fibrillation, atrial tachycardia, or high-degree atrioventricular block prior to implantation.

View Article and Find Full Text PDF

Following implantation, infections, inflammatory reactions, corrosion, mismatches in the elastic modulus, stress shielding and excessive wear are the most frequent reasons for orthopedic implant failure. Natural polymer-based coatings showed especially good results in achieving better cell attachment, growth and tissue-implant integration, and it was found that the inclusions of nanosized fillers in the coating structure improves biomineralization and consequently implant osseointegration, as the nanoparticles represent calcium phosphate nucleation centers and lead to the deposition of highly organized hydroxyapatite crystallites on the implant surface. In this study, magnetic nanoparticles synthesized by the co-precipitation method were used for the preparation of cellulose acetate composite coatings through the phase-inversion method.

View Article and Find Full Text PDF

Calcium Phosphate (CaP) Composite Nanostructures on Polycaprolactone (PCL): Synergistic Effects on Antibacterial Activity and Osteoblast Behavior.

Polymers (Basel)

January 2025

Division of Mechanical Engineering, College of Engineering, Wonkwang University, 460 Iksandae-ro, Iksan 54538, Jeonbuk, Republic of Korea.

Bone tissue engineering aims to develop biomaterials that are capable of effectively repairing and regenerating damaged bone tissue. Among the various polymers used in this field, polycaprolactone (PCL) is one of the most widely utilized. As a biocompatible polymer, PCL is easy to fabricate, cost-effective, and offers consistent quality control, making it a popular choice for biomedical applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!